User Manual
Code: SINUSPRO-800S
OFF-GRID SOLAR INVERTER SINUSPRO-800S 800 VA VOLT Polska
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-12-19
SINUSPRO-800S
2/5
The SINUSPRO-800S Solar Inverter is a device that allows
the use of solar energy to power devices requiring
alternating voltage 230V AC. This device is designed to
work in the off-grid system, which means that the power
outputs are intended only for direct supply of energy to
receivers.
The design of the SINUSPRO-800S inverter allows it to
work both as a redundant power source in the event of a
power grid failure, and as the main power source for
devices supported by an external grid only in the event of a
long-term lack of solar energy and battery discharge. High
flexibility of operating modes combined with very short
switching times allow the device to be used in many
situations.
The built-in AVR (Automatic Voltage Regulator) means that
the devices powered by the inverter are not exposed to
sudden changes or sags of the supply voltage. It is
especially important when powering sensitive electronic
devices, such as computers, TV sets or electronic
controllers, which are more and more often found in
various power tools and household appliances.
The built-in toroidal transformer compensates for different
reactive power of the receivers (you can combine
capacitive, inductive and resistive loads), it reacts very
flexibly to overloads, e.g. start-up of pumps, compressors
and engines.
Attention! For cooperation with the inverter, it is
recommended to use batteries adapted to work in the
buffer charging mode and prepared for the possibility of
deep discharge. Connecting other types of batteries to the
inverter may result in incorrect operation of the inverter or
damage to the battery.
Attention! The output part of the AC cabling should never
be connected to the mains (this also applies to N and PE
cables) or to the generator. Such a connection may cause
damage greater than a short circuit in the circuit.
Attention! The inverter should not be used to power life
support systems or other medical equipment.
Nominal power:
500 W
Apparent Power:
800 VA
Input voltage:
140 V ... 275 V AC
Input frequency:
45 ... 65 Hz
Output voltage:
230 V AC ± 3 % (Pure Sine Wave)
Output frequency:
50 Hz ± 0.3 Hz
Transfer time:
4 ms (typical), max. 6 ms
Number of outputs:
1 pcs CEE 7/5 ,
1 pcs CEE 7/3 (Schuko)
Voltage of the Solar Panels Section:
15 V ... 50 V DC
Battery Voltage:
12 V