Service Manual #513688 Rev.0
3
U411 Model Machines
1.3 COMPONENT
SETTINGS
Following are the settings for the components in the
U411 I2 machine.
A. COMPRESSOR WINDINGS
When testing the compressor windings the resistance
through the windings should be as follows:
B. CAPACITORS
Refer to the following table for the capacitance of all the
capacitors in the machine:
C. PUMP PRESSURE SWITCH
The pump pressure switch, located in the cabinet, main-
tains 21-24 psig in the mix line.
°F
Resistance
°F
Resistance
-22
176950
40
26100
-20
165200
42
24725
-18
154300
44
23400
-16
144200
46
22175
-14
134825
48
21000
-12
126125
50
19900
-10
118050
52
18875
-8
110550
54
17900
-6
103550
56
17000
-4
97075
58
16125
-2
91025
60
15325
0
85400
62
14550
2
80150
64
13825
4
75275
66
13150
6
70725
68
12500
8
66475
70
11875
10
62500
72
11300
12
58800
74
10750
14
55325
76
10250
16
52100
78
9750
18
49075
80
9300
20
46250
82
8850
22
43600
84
8450
24
41125
86
8050
26
38800
88
7675
28
36625
90
7325
30
34575
92
7000
32
32675
94
6675
34
30875
96
6375
36
29175
98
6100
38
27600
100
5825
D. TEMPERATURE CONTROL SENSOR
The following table shows the relationship between the
thermistor resistance and the suction line temperature.
Rating
Capacitor
Part
MFD
VAC
Compressor - Start 230638
88-106 MFD
330 VAC
Compressor - Start 231049
88-106 MFD
330 VAC
Compressor - Run
230653
40 MFD
370 VAC
Compressor - Run
231048
40 MFD
440 VAC
Motor - Start
230622
200 MFD
250 VAC
Motor - Run
231075
30 MFD
370 VAC
Fan Motor
230654
5 MFD
400 VAC
Cab Compressor
230667
80 MFD
300 VAC
Compressor Electrical
S to C
R to C
282076
1 PH
3.31
Ω
1.28
Ω
282116
1 PH
1.70
Ω
1.02
Ω
282117
3 PH
1.91
Ω
1.54
Ω
282111
1 PH
16.40
Ω
10.20
Ω
Содержание Stoelting U411
Страница 1: ...Model U411 SERVICE MANUAL Manual No 513688 Rev 0...
Страница 2: ......
Страница 6: ......
Страница 10: ...Service Manual 513688 Rev 0 4 U411 Model Machines...
Страница 14: ...Service Manual 513688 Rev 0 8 U411 Model Machines...
Страница 19: ...Service Manual 513688 Rev 0 13 U411 Model Machines 3 5 PUMP PARTS CONTINUED...