6
D. The floor model freezers are equipped with air-cooled
condensers and require correct ventilation. The front of
the freezer is the air intake and must be unobstructed.
Air discharges out of the rear of the unit. Do not obstruct
the discharge. Allow a 6" (15.2 cm) clearance behind
the unit (Fig. 8).
CAUTION
FAILURE TO PROVIDE ADEQUATE VENTILATION WILL
VOID WARRANTY!
Figure 8
Space and Ventilation Requirements
E. Place the ON-OFF-STIR ONLY toggle switch in the
OFF position. This switch is located on the lower left of
the freezer, under the drip tray and cover.
F. Connect the power cord. The plug is designed for 115
volt/15 amp duty. The unit must be connected to a
properly grounded receptacle. The electrical cord
furnished as part of the freezer has a three prong
grounding type plug (Fig.9). The use of an extension
cord is not recommended. If one must be used, use one
with a wire, size 12 gauge or heavier, with a ground. Do
not use an adaptor to avoid grounding equipment.
CAUTION
DO NOT ALTER OR DEFORM PLUG IN ANY WAY!
Figure 10
Installing Sani-tray and Cover
Figure 9
Electrical Plug
G. Install the sani-tray, cover and miscellaneous parts
on the freezer (Fig. 10).
Содержание Stoelting 100C
Страница 1: ...Model 100C 100F 2217G SERVICE MANUAL Manual No 513554...
Страница 2: ......
Страница 16: ...8...
Страница 28: ...20...
Страница 30: ...22...
Страница 40: ...32...
Страница 46: ...38 Figure 50 Model 100C Exploded View...
Страница 48: ...40 Figure 51 Model 100F Exploded View...
Страница 50: ...42 Figure 52 Model 2217G Exploded View...