28 Flexvent™ installation manual
TROUBLESHOOTING
Problem
Might be Caused By
Course of Action
Unit will not operate
— logo is not
illuminated.
There is no power.
The ANSUL
®
Fire Suppression
System was not properly
commissioned or needs
service.
•Reconnect to electrical power.
•Reset circuit breaker for unit.
•Contact Vollrath Technical Services.
Contact an authorized ANSUL
®
representative for repair.
Low Pressure Indicator
is illuminated and
cooking unit will not
turn on.
Particulate or Grease Filters
are out of position, missing, or
are not the correct type.
Properly install correct filters.
High Pressure Indicator
is illuminated and
cooking unit will not
turn on.
Particulate or Grease Filters
are dirty or are not the correct
type.
Install correct, clean filters.