PRODUCT OVERVIEW

Congratulations on your purchase! Your new Vollara® Air & Surface Pro is designed to provide years of trouble-free, low 
maintenance operation. Be sure to read and follow all service procedures outlined in this owner’s manual, and use only 
genuine Vollara replacement parts.

CONTENTS

Product Overview  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

Specifications  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 2

Important Safety Instructions    .   .   .   .   .   .   .   .   .   .   .   .   . 3

For Canadian customers only .   .   .   .   .   .   .   .   .   .   .   .   .   . 4

Inspection & Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

Unit Features   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 5

Operation  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 6

Settings & Adjustments    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 6

LED Display .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

Maintenance Reminders  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

General Maintenance.     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     . 8

Removing the Filter Assembly.     .     .     .     .     .     .     .     .     .     .     .     .     . 9

Uninstalling the Optional HEPA Filter Sheet   .   .   .   .   .   .   10

Removing the ActivePure

®

 Cells .   .   .   .   .   .   .   .   .   .   .   .   11

Installing the ActivePure

®

 Cells   .   .   .   .   .   .   .   .   .   .   .   .   11

Troubleshooting  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   12

Replacement Parts & Service .     .     .     .     .     .     .     .     .     .     .     .     .     13

Warranty Information   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  14

FCC Declaration & Responsible Party  .   .   .   .   .   .   .   .   .   15

GENERAL INFORMATION

 

Vollara, LLC reserves the right to change or 
modify any specification without notice.

SPECIFICATIONS

Vollara Air & Surface Pro

• Model Number: A1040J
• Sales Number: 9940062

Technology

:

• ActivePure

®

 (2 Cells) — ozone-free

• HEPA Filter Screen
• Activated Carbon Filter
• Carbon Brushes

Electrical:

• Input Voltage: 100 ~ 240 VAC; 50/60 Hz 
• External power supply: DC 24 Volts; 1.5 Amps Max
• Power Consumption: 43 Watts Max 
• Conforms to UL STD 867

Mechanical:

• Nominal Airflow Rate: 40-60 CFM Adjustable Speed Fan

Sound Level:

• 45 dB(A) on low; 55 dB(A) on high

Weight & Dimensions:

• 7.6 lbs (3.45 kg)
• 11.75” H x 9.5” W x 10” D  
  (29.8 cm x 24.1 cm x 25.4 cm)

Operating Temperature:

• 34°F – 100°F (1.6°C   – 38°C)

Recommended Maximum Coverage  
in a Contiguous Space

1

:

• Up to 2,000 sq. ft. (185m

2

) depending on occupant  

   density and other factors

1

. High density commercial  

   not to exceed  500 sq. ft. (46m

2

).

Warranty:

• Limited three (3) year warranty

1. Assumes 8 foot ceilings. Solutions should be customized based upon a variety of factors 
including HVAC system capabilities and settings, air flows taking into account walls, air 
pressure, and doors, ambient air temperatures and humidities, variable density, known 
VOC concentrations, and other layers of protection.

If you have any questions concerning this, or any Vollara product, contact your Vollara 

Independent Business Owner or Customer Service at 800.989.2299 or  

email [email protected]

Record information regarding your new Vollara Air & 
Surface Pro here. Retain for future reference.

Model No.

Serial No.

Date of Purchase

Vollara Independent Distributor/Contractor:

Name

Phone No.

Address

FILL IN AND SAVE

STORAGE AND DISPOSAL 

Do not dispose of this product as household waste. Electrical 
waste

 

and electronic products should be appropriately recycled as 

required by practices established by your local authority.

95760-CHN-1

EPA Est.

Содержание A1040J

Страница 1: ...READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION PORTABLE SURFACE AIR PURIFICATION SYSTEM x2...

Страница 2: ...to UL STD 867 Mechanical Nominal Airflow Rate 40 60 CFM Adjustable Speed Fan Sound Level 45 dB A on low 55 dB A on high Weight Dimensions 7 6 lbs 3 45 kg 11 75 H x 9 5 W x 10 D 29 8 cm x 24 1 cm x 25...

Страница 3: ...om outlet pull firmly on the plug DO NOT unplug by pulling on the cord Always unplug the unit before moving or cleaning or whenever the unit is not in use DO NOT use outdoors or on wet surfaces DO NOT...

Страница 4: ...is device DIRECTIONS FOR USE Plug the cord into a working electrical outlet leaving at least one inch of open area to allow for airflow Please see owner s manual for detailed instructions on using han...

Страница 5: ...TURES 1 Remove protective packaging 2 Remove unit from shipping carton 3 Remove all protective materials 4 Check for shipping damage and loose or broken parts 5 Read Owner s Manual thoroughly prior to...

Страница 6: ...5 Push the A PURE A PURE x2 button twice to set it to A PURE x2 level which will be illuminated on the screen 6 Push the Fan button four times to reach the highest speed 5th level A PURE MODE The uni...

Страница 7: ...The perform cleaning CLEAN indicator will come on approximately every 180 days for optimal performance it is recommended to perform cleaning on your unit every 30 days Clean the Filter Assembly See Pa...

Страница 8: ...flashing in red ActivePure Cell is possibly damaged In this case contact your Independent Distributor Contractor or Vollara Customer Service at 800 989 2299 Resetting the Reminders The reminders you...

Страница 9: ...ributor Contractor or Vollara Customer Service at 800 989 2299 for replacement filters see pages 8 9 for removal and installation instructions NOTE Filter Assembly life will vary based on the operatin...

Страница 10: ...duce VOCs and other contaminants NOTE Removing the Optional HEPA Filter Sheet will increase the airflow of the unit UNINSTALLING THE OPTIONAL HEPA FILTER SHEET Unplug the unit before performing any ma...

Страница 11: ...mbscrews 4 Slide the ActivePure Cell down and out of the unit INSTALLING THE ACTIVEPURE CELLS WARNING Unplug the unit before performing any maintenance procedures Do not operate the Vollara Air Surfac...

Страница 12: ...ment appears unsuccessful Problem Lack of air movement improper placement of the unit Symptom Visual haze of smoke and or particulate remain within the environment Problem Lack of ionization and or ai...

Страница 13: ...r Assembly 9950238 Power Supply with U S Euro Plug 9950242 To order replacement parts contact your independent Vollara Business Owner or Vollara Customer Service for further assistance at 1 800 989 22...

Страница 14: ...anty coverage prior to purchasing a product contact Vollara Customer Service at 800 989 2299 with the serial number located on the back of the unit EXCLUSION OF OTHER WARRANTIES AND CONDITIONS EXCEPT...

Страница 15: ...This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However th...

Страница 16: ...ol VA 24201 800 989 2299 Made in P R C Vollara LLC All Rights Reserved For information regarding the use of this product please contact your Vollara Independent Business Owner or Customer Service at 8...

Отзывы: