– Remove heat exchanger -4- with seal -3- from combustion air
blower - V6- -2-.
Installing
Install in reverse order of removal, observing the following:
Note
♦
Note that seal -3- must be renewed when heat exchanger -4- is installed.
♦
If heat exchanger is renewed, flame monitor - G64- and overheating sensor - G189- (combination sensor)
must be transferred.
– Fit heat exchanger -4- with new seal -3- on combustion air
blower - V6- -2-.
– Tighten bolts -1- in diagonal sequence
– Perform a functional check after completing all work on the
heater unit.
Transporter 2020 ➤
Auxiliary heater - Edition 04.2020
7. Auxiliary air heater
49