Unvented Hot Water Cylinder
- 25-
4.7
Solar controller - When the solar controller is used as the normal control thermostat on
the cylinder and the cylinder incorporates a high limit thermostat for the solar circuit
4.8
T&P
Technical data
Max Pressure: 7 bar
Max Temperature: 90°C
4.9
Motorized Zone Valve
Technical data
240V, 0.04°, 6/5W, 50/60Hz
Max Diff. Press. : 55.2kPa (8psi)
Max. Stat. Press. : 863 kPa (125 psi)
Max. Fluid Temp. : 5-88 °C (40-190°F)
Max. Ambient Temp. : 52°C (125°F)
Hot water Only
4.10
Dual Thermostat
Technical data
Temperature range: 25±5 ÷ 65±3°C
Temperature differential: Δt 8±2 K
Limit temperature: FIX 80±3°C
Fail safe: YES
Differential (Manual Reset): 20±5°C
Max. body temperature: T 80°C
Max. bulb temperature: T 125°C
Ambient temperature effect: -0.12°C/°C *
Fairlead: M20x1.5
Degree of protection: IP40
Contact rating: N-A 10(2,5)A/250V~
Change in switching pint refer to maximum change of the value of ambient
temperature
4.11
Drainage
Typical drain arrangement and system design.