5.7 Pole Mounting on T75 Stud Bracket

Figure 5.20: Heavy Duty Top Hat Casting

Parts required:

Heavy Duty Top Hat 
Casting

Black - IT2238
White - IT2237

Figure 5.21: Pole mount bracket removal

Figure 5.22: Mounting to the T75 stud  bracket

Step 1:

Remove the M12 bolt from the pole mount 
bracket.

Step 2:

Mount the pole mount bracket to the T75 stud 
bracket.

Содержание Air Vantage

Страница 1: ...voidacoustics com Air Vantage Breathtaking performance exceptional design USER GUIDE V2 0...

Страница 2: ...t notice For the latest online version visit www voidacoustics com Void Acoustics and the Void logo are registered trademarks of Void Acoustics Research Ltd in the United Kingdom USA and other countri...

Страница 3: ...specifications 7 3 5 Air Vantage dimensions 8 4 Cable and Wiring 9 4 1 Electrical safety 9 4 2 Cable considerations for fixed installations 9 4 3 Air Vantage wiring diagram 9 4 4 Bias D1 Q1 Q2 Phoeni...

Страница 4: ...e of causing permanent hearing damage from prolonged exposure The higher the sound level the less exposure needed to cause such damage Avoid prolonged exposure to the high sound levels from the loudsp...

Страница 5: ...ers are heavy 23 5 kg 51 8 lbs and require a minimum two people to lift Undo the four butterfly catches on the transport case then remove the lid making sure the lid is clear before moving sideways If...

Страница 6: ...ation In buying this product you are now part of the Void family and we hope using it brings you years of satisfaction This guide will help you both use this product safely and ensure it performs to i...

Страница 7: ...t 133 dB peak Driver configuration 1 x 12 1 x 1 5 coax Mounting Tilt adjustable mount optional Dispersion 70 H x 40 V Connectors 1 x 4 pole speakONTM NL4 Height 415 mm 16 3 Width 719 mm 28 3 Depth 660...

Страница 8: ...Page 8 UG10527 2 0 Air Vantage User Guide V2 0 3 About 719 28 3 108 4 3 51 2 0 305 12 0 276 10 9 415 16 3 660 26 0 3 5 Air Vantage dimensions Figure 3 3 Dimensions...

Страница 9: ...ns should be compliant with the following standards IEC 60332 1 Fire retardancy of a single cable IEC 60332 3C Fire retardancy of bunched cables IEC 60754 1 Amount of Halogen Gas Emissions IEC 60754 2...

Страница 10: ...igure 4 3 Bias Q1 Q2 4 5 Bias Q3 Q5 speakONTM wiring 1 1 1 1 Bias D1 Q1 Q2 Single channel Output LF 12 and HF 1 5 Max parallel units 4 2 load to amplifier Bias Q3 Q5 Single channel Output LF 12 and HF...

Страница 11: ...tallation of wall brackets Remember that all personnel have a duty of care to themselves to their assistants to the venue staff and to the public Before lifting any part of the system above head heigh...

Страница 12: ...t Figure 5 3 T75 Pole Bracket positioning Figure 5 2 M8 socket cap removal Step 1 Lay a soft lint free rug clear of debris on the working surface to avoid damage to the loudspeaker Place the Air Vanta...

Страница 13: ...not to over tighten Figure 5 6 Air Vantage positioning Step 5 Finally ensure that the Air Vantage loudspeaker is safely in place by tightening the wingnut on the T75 pole bracket Figure 5 5 Air Vanta...

Страница 14: ...Figure 5 9 T75 Stud Bracket positioning Step 2 Place the T75 Stud Bracket in position and insert the M8 socket cap Allen bolts Figure 5 8 M8 socket cap removal Step 1 Lay a soft lint free rug clear o...

Страница 15: ...Page 15 UG10527 2 0 Air Vantage User Guide V2 0 5 3 Stud Bracket Mounting Figure 5 10 T75 Stud Bracket fixing Step 3 Fix all four M8 socket cap Allen bolts taking care not to over tighten...

Страница 16: ...must be fitted when securing the bracket to the wall Figure 5 12 T75 Wall Bracket with extension piece fixing Step 1 Attach the extension piece to the T75 Wall Bracket with the M12 nyloc nut Figure 5...

Страница 17: ...ir Vantage User Guide V2 0 5 4 Wall Mounting Figure 5 14 Air Vantage fixing Step 3 Rotate the Air Vantage loudspeaker into the desired position and tighten the M12 nyloc bolt Maximum rotation Vertical...

Страница 18: ...ts must be fitted when securing the bracket to the wall Figure 5 16 Air Vantage positioning Step 1 Remove the T75 stud bracket and follow the steps in section 5 3 to attach it to the Air Vantage Lift...

Страница 19: ...ety wire attachment Step 3 Attach the secondary bond safety wire to the central box section The safety wire must be rated to 23 5 kg 51 8 lbs with a safety factor conforming to local regulations Figur...

Страница 20: ...0 Heavy Duty Top Hat Casting Parts required Heavy Duty Top Hat Casting Black IT2238 White IT2237 Figure 5 21 Pole mount bracket removal Figure 5 22 Mounting to the T75 stud bracket Step 1 Remove the M...

Страница 21: ...ir Vantage loudspeaker into position taking care to follow the safe handling positions detailed in section 2 Figure 5 24 Adjusting the loudspeaker position Step 4 Adjust the loudspeaker into the desir...

Страница 22: ...s Bracket Step 1 Remove the T75 stud bracket and follow the steps in section 5 3 to attach it to the Air Vantage Remove the wing nuts from the couplers and position the bracket in the desired location...

Страница 23: ...led in section 2 Figure 5 29 Air Vantage truss mount detail Step 4 Attach the Air Vantage the bracket with the M12 nyloc nut using a 19 mm ratchet spanner Figure 5 30 Safety wire attachment Step 5 Att...

Страница 24: ...hat your dealer will need to see a copy of your sales receipt as proof of purchase so please have this to hand when applying for return authorisation 6 2 Shipping and packing considerations When sendi...

Страница 25: ...he centre of the low frequency transducer coupling with its horn by using the 718 mm 28 3 baffle diameter of such horn to achieve greater SPL and pattern control on high frequencies Performance specif...

Страница 26: ...usa voidacoustics com HEAD OFFICE Void Acoustics Research Ltd Unit 15 Dawkins Road Industrial Estate Poole Dorset BH15 4JY United Kingdom Call 44 0 1202 666006 Email info voidacoustics com Void Acoust...

Отзывы: