Страница 2: ...UE product All products brought to you by VOGUE are manufactured to the highest standards of performance and safety and as part of our philosophy of customer service and satisfaction We hope you will enjoy using your purchase for many years to come 2 ...
Страница 3: ...elcome Section 4 Warranty Page 5 General Safety 7 Specification 7 Components 11 Installation 18 Operating Your Range hood 21 Cleaning and Maintenance 22 Troubleshooting Technical Data 23 Environmental Protection 3 ...
Страница 4: ... rights and remedies in respect of the product that the consumer has under the Competition and Consumer Act 2010 and similar state and territory laws Our goods come with guarantees that cannot be excluded under the New Zealand Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled t...
Страница 5: ...ternal air evacuation Make sure to follow your local laws that apply to external air evacuation when installing and using the range hood Electrical safety and cord handling Voltage and frequency Before plugging the unit into an appropriate electrical outlet make sure your outlet voltage and circuit frequency correspond to the voltage stated on the appliance rating label Power cord Check the cord r...
Страница 6: ... cooking Do not use an open flame for cooking underneath this rangehood Open flames can damage the filters and present a fire hazard Unattended Do not leave the range hood unattended during use After use Make sure to switch off the range hood after use and before cleaning CAUTION Do not touch the light bulbs after the appliance has been used as they may be hot Let them cool down before cleaning an...
Страница 7: ...on Kit The installation kit contains the following parts Part ID Illustration Description QTY 1 Range hood 1 2 SS Inner flue extension cover 1 1 3 SS Outer flue cover 1 4 Expandable 150mm ducting pipe 1 Part ID Illustration Description QTY 5 Screws ST4 x 30mm 9 6 Screws ST4 x 8mm 2 7 Wall Plugs 8mm 9 8 Range hood wall mounting bracket 1 9 Outer flue cover bracket 1 10 Inner flue extension cover br...
Страница 8: ...n Kit The installation kit contains the following parts Part ID Illustration Description QTY 1 Range hood 1 2 SS Inner flue extension cover 1 1 3 SS Outer flue cover 1 4 Expandable 150mm ducting pipe 1 Part ID Illustration Description QTY 5 Screws ST4 x 30mm 9 6 Screws ST4 x 8mm 2 7 Wall Plugs 8mm 9 8 Range hood wall mounting bracket 1 9 Outer flue cover bracket 1 10 Inner flue extension cover bra...
Страница 9: ...allation Kit The installation kit contains the following parts Part ID Illustration Description QTY 1 Range hood 1 2 SS Inner flue extension cover 1 3 SS Outer flue cover 1 4 Expandable 150mm ducting pipe 1 Part ID Illustration Description QTY 5 Screws ST4 x 30mm 9 6 Screws ST4 x 8mm 6 7 Wall Plugs 8mm 9 8 Range hood wall mounting bracket 1 9 Outer flue cover bracket 1 10 Inner flue extension cove...
Страница 10: ...he installation kit contains the following parts Part ID Illustration Description QTY 1 Range hood 1 2 SS Inner flue extension cover 1 1 3 SS Outer flue cover 1 4 Expandable 150mm ducting pipe 1 Part ID Illustration Description QTY 5 Screws ST4 x 30mm 9 6 Screws ST4 x 8mm 6 7 Wall Plugs 8mm 9 8 Range hood wall mounting bracket 1 9 Outer flue cover bracket 1 10 Inner flue extension cover bracket 1 ...
Страница 11: ... as below picture by means of an extraction duct enamel aluminium flexible pipe or inflammable material with an interior diameter of 150mm b Before installation turn the unit off and unplug it from the outlet c The cooker hood should be placed at a distance of 65 75cm above the cooking plane for best effect 11 ...
Страница 12: ... the range hood and appliance supplied with energy other than electricity are simultaneously in operation the negative pressure in the room must be not exceed 4 Pa 4 10 5 Bar Drill 3 x 8mm holes to accommodate the bracket Screw and tighten the bracket onto the wall with the screws screw plugs provided 1 Offer up the cooker hood and hang onto the wall bracket hook 12 ...
Страница 13: ... the upper chimney into lower chimney Then pulling out the upper chimney upwards Adjust to reach the height required Sliding the chimney to adjust the chimney height When the height you required is reached then hang the fixing hole to the fixing screws as showed in below pictures 13 ...
Страница 14: ...imney hood for Model No 330294 330295 By put the inner chimney into upper chimney Then pulling out the upper chimney upwards Adjust to reach the height required Fix the lower chimney with 2 pcs of 4x8mm screws 14 ...
Страница 15: ...s reached then fix 2 pcs of 4x8mm screws onto the hole fixing with plate I as showed in below pictures Drill 2 x 8mm holes to accommodate the plate II Screw and tighten the plate II onto the wall with 2 screws provided Assemble the chimney onto the unit and fix it with 2 screws 15 ...
Страница 16: ... chimney Outer Installation Vent inside NOTE Carbon Filter not supplied these can be purchased as an accessory If you do not have an outlet to the outside exhaust pipe is not required and the installation is similar to the one show in section Installation Vent outside Activated carbon filter can be used to trap odours In order to install the activated carbon filter the grease filter should be deta...
Страница 17: ...eat the same on the other side NOTE Make sure the filter is securely locked Otherwise it would loosen and cause dangerous When activated carbon filter attached the suction power will be lower Remove all blue protective film on chimney and cooker hood the installation is now finished 17 ...
Страница 18: ... lot of steam Use this setting when simmering Medium Speed Setting The medium speed setting is used the standard setting for normal cooking This setting is recommended for most types of cooking High Speed Setting Use the high speed setting when cooking on multiple zones or when the density of smoke steam increases Light Button Press the light button symbol to turn the LED lights on or off 18 ...
Страница 19: ... 1 second Digital display will flashing into 5 minutes count down after 5 minutes motor light will turn off automatic Buzzer sound on Speed plus button For increasing the speed of the fan Speed decrease button For decreasing the speed of the fan Light button Short press for lamp power control Long press 1 For turning off the Cleanning symbol reset total working time when Cleanning symbol is on mot...
Страница 20: ... setting is used the standard setting for normal cooking This setting is recommended for most types of cooking High Speed Setting Use the high speed setting when cooking on multiple zones or when the density of smoke steam increases B Booster Button Extra high power for an intensive airflow press B button after 5 minutes will turn back to high speed setting Light Button Press the light button symb...
Страница 21: ...l saturate the filter It can be easily cleaned with warm water and washing up liquid alternatively the filters can be cleaned in your dishwasher Please ensure no other items are washed with the filters they must be washed separately to prevent food becoming trapped in the gauze Cleaning the grease filters in the dishwasher may lead to discolouration this is normal and is a not a fault with the pro...
Страница 22: ...n engineer is concerned that damage will be caused to the appliance or your kitchen then they will not complete a repair This includes situations where the range hood has been tiled in or sealed in with a sealant Please refer to the conditions of that appear on the warranty card a the rear of this user manual Fault Common Cause Common Solutions The lights work however The motor is blocked or jamme...
Страница 23: ...he environment and human health which could otherwise be caused by inappropriate waste handling of this product The symbol on the product indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment Disposal must be carried out in accordance with local environmental regu...