background image

18

© 2022 United States Stove Company

MAINTENANCE

BLOWER MOTORS

Clean the air holes on the motors of both the exhaust and 

distribution blowers annually. Remove the exhaust blower 

from the exhaust duct and clean out the internal fan blades 

as part of your fall start-up. If you have indoor pets your 

power motors should be inspected monthly to make sure 

they are free of animal hair build up. Animal hair build up 

in blowers can result in poor performance or unforeseen 

safety hazards.

PAINTED SURFACES

Painted surfaces may be wiped down with a damp cloth. If 

scratches appear, or you wish to renew your paint, contact 

your  authorized  dealer  to  obtain  a  can  of  suitable  high-

temperature paint.

GLASS

We recommend using a high-quality glass cleaner. Should 

a buildup of creosote or carbon accumulate, you may wish 

to use 000 steel wool and water to clean the glass. DO 

NOT use abrasive cleaners. DO NOT perform the cleaning 

while the glass is HOT. Do not attempt to operate the unit 

with broken glass. Replacement glass may be purchased 

from your U.S. Stove dealer. If the glass is broken, follow 

these removal procedures:

1.  Once the heater has cooled, remove the door from the 

heater.

2. 

Remove the rope gasket from the door followed by the 

nuts holding the glass retainer in place.

3.  While wearing gloves, carefully remove any loose 

pieces of glass from the door frame.

4.  Replace the glass and gasket, making sure the gasket 

runs the full perimeter of the glass edge.

5. 

Re-install the retainer and eight nuts and rope gasket 

using high-temperature silicone to adhere the gasket 

to the door.

6. 

Never use substitute materials for the glass.

DO  NOT  abuse  the  door  glass  by  striking,  slamming,  or 

similar trauma. Do not operate the stove with the glass 

removed, cracked, or broken.

FALL START UP

Prior to starting the first fire of the heating season, check 

the outside area around the exhaust and air intake systems 

for obstructions. Clean and remove any fly ash from the 

exhaust venting system. Clean any screens on the exhaust 

system and on the outside air intake pipe. Turn all of the 

controls on and make sure that they are working properly. 

This is also a good time to give the entire stove a good 

cleaning throughout.

SPRING SHUTDOWN

After  the  last  burn  in  the  spring,  remove  any  remaining 

pellets from the hopper and the auger feed system. Scoop 

out the pellets and then run the auger until the hopper 

is  empty  and  pellets  stop  flowing  (this  can  be  done  by 

pressing  the  “ON”  button  with  the  viewing  door  open). 

Vacuum  out  the  hopper.  Thoroughly  clean  the  burn  pot, 

and firebox. It may be desirable to spray the inside of the 

cleaned hopper with an aerosol silicone spray if your stove 

is in a high humidity area. The exhaust system should be 

thoroughly cleaned.

MAINTENANCE SCHEDULE

Use the following as a guide under average use conditions. 

Gaskets around door and door glass should be inspected 

and repaired or replaced when necessary.

Daily

Weekly

Monthly or 

as needed

Burn Pot

Stirred

Empty

Combustion 

Chamber

Brushed

Ashes

Check

Empty

Interior Chambers

Vacuumed

Combustion 

Blower Blades

Vacuumed / 

Brushed

Convection Blower 

Impeller

Vacuumed / 

Brushed

Vent System

Cleaned

Gaskets

Inspected

Glass

Wiped

Cleaned

Hopper (end of 

season)

Empty & 

Vacuumed

Содержание VG5717-P

Страница 1: ...r fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Futu...

Страница 2: ...heater meets the 2020 U S Environmental Protection Agency s crib wood emission limits for wood heaters sold after May 15 2020 Under specific EPA test conditions this heater has been shown to deliver heat at a rate of 11 871 to 30 884 Btu hr This heater achieved a particulate emissions rate of 1 6 g hr when tested to method ASTM E 2779 and 77 efficiency WARNING IT IS AGAINST FEDERAL REGULATIONS TO ...

Страница 3: ..._________________________________________ If no Date of inspection of existing venting system ___________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in...

Страница 4: ...led wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory installed wiring harnesses to the control panel as shown 4 Secure the control panel to the top of the stove with two sheet metal screws ...

Страница 5: ...ED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONTOF OR OVERTHE HEATER DO NOT ROUTE THE CORD IN FOOTTRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BURNING FUEL CREATES CARBON MONOXIDE AND CAN BE HAZARDOUS TO YOUR HEALTH IF NOT PROPERLY VENTED ATTENTION A W...

Страница 6: ...on combustible surface should be large enough to cover at least the area under the product and 6 153 mm beyond the front and beyond each side of the fuel loading and ash removal openings Floor protection must extend under and 2 51 mm to each side of the chimney tee for an interior vertical installation Canadian Installations require a minimum of 18 458 mm beyond the front of the unit and 8 204 mm ...

Страница 7: ...nimum or 36 914 mm above the roof line of the mobile home and must be installed using a certified ceiling fire stop and rain cap When moving your mobile home all exterior venting must be removed while the mobile home is being relocated After relocation all venting must be reinstalled and securely fastened Outside Air is mandatory for mobile home installation See Outside Air Supply section and your...

Страница 8: ...eriodic cleaning of the exhaust system 90 degree elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of the stove Each elbow or tee reduces draft potential by 30 to 50 All joints in the vent system must be fastened by at least 3 screws and all joints must be sealed with Hi Temp RTV silicone sealant to be airtight The area where the vent pipe penetrates to the exterior ...

Страница 9: ...ation which meets the requirements of this manual but in an area where it does not interfere with the house framing wiring etc 2 Install a non combustible hearth pad underneath the pellet stove This pad should extend at least 6 152 mm in front of the unit 3 Place the pellet stove approximately 15 381 mm away from the interior wall Locate the center of the exhaust pipe of your unit This point shoul...

Страница 10: ...he house At this point a 3ft 0 91m minimum section of pipe should be added with a horizontal cap which would complete the installation A support bracket should be placed just below the termination cap or one every 4ft 1 22m to make the system more stable If you live in an area that has heavy snowfall it is recommended that the installation be taller than 3ft 0 91m to get above the snowdrift line T...

Страница 11: ...on a horizontal run and use as few elbows as possible If an offset is required it is better to install 45 degree elbows rather than 90 degree elbows Venting your pellet stove into an existing Class A 6 chimney System 1 IMPORTANT If you are installing your pellet stove as a replacement to an existing wood stove you can install your pellet stove using the existing class A 6 venting system You must h...

Страница 12: ...t range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled with a Thermostat Separate LEDs to the left of the two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat mode Manu...

Страница 13: ...to remove most fines Binders Some pellets are produced with materials to hold the together or bind them High ash content Poor quality pellets will often create smoke and dirty glass They will create a need for more frequent maintenance You will have to empty the burn pot plus vacuum the entire system more often Poor quality pellets could damage the auger We cannot accept responsibility for damage ...

Страница 14: ...ove should be set on setting 1 with the damper fully closed Setting 4 will give you a medium high burn and setting 2 will give you a medium low burn If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down If the stove shuts down push the On Off button to re start your stove The stove will have to fully shut down and turn off before you ...

Страница 15: ...ch has two functions A To recognize an overheat situation in the stove and shut down the fuel feed or auger system B In case of a malfunctioning convection blower the high temperature snap disc will automatically shut down the auger preventing the stove from overheating NOTE On some units once tripped like a circuit breaker the reset button will have to be pushed before restarting your stove On ot...

Страница 16: ... behind the right side panel To access the igniter remove the air inlet tube and cover 2 screws The auger motor is located in the center rear of the unit Note When cleaning take care not to damage the fan blades If a vacuum is used to clean your stove we suggest using the AV15E AshVac vacuum The AV15E AshVac is designed for ash removal Some regular vacuum cleaner i e shop vacs may leak ash into th...

Страница 17: ...d if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combustible it may impede the normal exhaust flow It should therefore be periodically removed ASH REMOVAL DISPOSAL CAUTION ALLOW THE STOVE TO COOL BEFORE PERFORMING ANY MAINTENANCE OR CLEANING ASHES MUST BE DISPOSED IN A METAL CONTAINER WIT...

Страница 18: ... using high temperature silicone to adhere the gasket to the door 6 Never use substitute materials for the glass DO NOT abuse the door glass by striking slamming or similar trauma Do not operate the stove with the glass removed cracked or broken FALL START UP Prior to starting the first fire of the heating season check the outside area around the exhaust and air intake systems for obstructions Cle...

Страница 19: ...tion of this manual Close the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blade If oiling the blower does not help the blower may be bad The stove is being left on the highest setting ...

Страница 20: ...res to the air switch Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If there is power the blower is bad If there is not make sure the control board is sending power to the air switch Control board not sending power to combustion blower If there is ...

Страница 21: ...g the auger pin then remove the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the lower bearing of the auger Pull the auger out of the tube to free the jam The auger motor has failed Remove the auger motor from the auger shaft and try to run the unit If the mo...

Страница 22: ...opper is open When operating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure connections Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by remo...

Страница 23: ... Smell Coming Back Into The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that has a temperature rating on 500 degree F or higher Also seal joints with UL 181 AP foil tape Also make sure the square to round adapter piece on the combustion blower has been p...

Страница 24: ...74 1 8 X 1 Window Gasket W Adhesive 7 28 ft 2 893159 Clear Glass 1 3 88324 1 Rope Gasket 5 17 ft 4 80780 IR Remote 1 5 893629 Burnpot Assembly 1 6 80491 Microswitch 1 7 80882 Control Board Assembly 1 8 80549 Pressure Switch 1 9 88100 Blower Gasket 1 10 80868 Combustion Blower 1 11 88118 Ignitor Flange Gasket 1 12 80869 Ceramic Ignitor 1 13 80781 Auger Motor 1 14 80610 Snap disc Surf Mt Low Limit P...

Страница 25: ...e ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the unit Other information that may be needed would be the part number and part description of the item s in question Part numbers and descriptions can be found in the Repair Parts section of this manual Once th...

Страница 26: ...__ Engineer Name ______________________________________ License No _________________________________________ Company ____________________________________________ Telephone No _______________________________________ Stove Inspected Chimney Swept Items Replaced ______________________________________ Service 02 Date ________________________ Engineer Name ______________________________________ License...

Страница 27: ... 2022 United States Stove Company 27 NOTES ...

Страница 28: ..._______________ Service de 07 Date _______________________ Nom de l ingénieur __________________________________ N de licence _______________________________________ Compagnie _________________________________________ N de téléphone ____________________________________ Poêle Inspecté Cheminée balayée Articles Remplacé __________________________________ Service de 02 Date _______________________ No...

Страница 29: ...areil Lors de la commande de pièces de rechange les informations contenues dans ce manuel vous aideront à vous assurer que les bons articles sont commandés Avant de contacter le service client notez le numéro de modèle et le numéro de série de cet appareil Cette information se trouve sur l étiquette de certification apposée à l arrière de l appareil D autres informations qui pourraient être nécess...

Страница 30: ...8846 Support De Moteur De Tarière 1 20 80782 Ventilateur De Combustion 1 21 88308 Joint De Soufflante 1 22 86896 Tube Soudeur 1 23 80607 Allumeur 1 24 40867 Transition Ventilateur 1 25 80781 Moteur De Tarière 1 26 28845 Capot Moteur 1 27 28604 Panneau Arrière 1 28 28889 Support De Commutateur De Pression 1 29 80549 Interrupteur À Vide 1 30 80609 Thermodisque Haute Limite 1 31 80779 Thermostat Mural ...

Страница 31: ... 2022 United States Stove Company 21 26 34 32 28 29 30 31 27 25 22 21 20 23 24 19 17 18 16 14 15 9 8 7 6 1 4 5 2 3 10 11 12 13 PIÈCES DE RECHANGE ...

Страница 32: ...ois par seconde Cela indique que le poêle fonctionne normalement et qu une condition de température excessive existe provoquant l arrêt du combustible Indicateur de réglage du niveau de chaleur Heat Range clignotant lentement une fois par seconde Cela indique que le poêle est en condition de réduction essayant d éviter un arrêt dû à une température excessive DÉFAUTS D USINE Pour renvoyer les comma...

Страница 33: ...à vis sans fin est bloqué ou il y a une voûte de combustible dans la trémie qui empêche le combustible de s écouler dans le système d approvisionnement à vis sans fin PROBLÈME CAUSE L allumeur automatique n allume pas le combustible dans le pot de combustion Le poêle ne démarre pas un feu quand le bouton ON marche est pressé Mettez le poêle en position OFF arrêt Retirez le combustible non brûlé du...

Страница 34: ...du verre en place 3 Tout en portant des gants retirez soigneusement les morceaux de verre détachés du cadre de la porte 4 Remplacez la vitre et le joint en vous assurant que le joint parcourt tout le périmètre du bord du verre 5 Réinstaller le dispositif de retenue et les huit écrous et le joint de corde à l aide de silicone haute température pour faire adhérer le joint à la porte 6 N utilisez jam...

Страница 35: ...er la totalité du système avant chaque saison de chauffage Pour nettoyer la cheminée déconnecter l évacuation du poêle CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d évacuation Bien qu elles ne soient pas combustibles elles peuvent gêner le flux normal d évacuation Elles doivent donc être périodiquement éliminées ENLÈVEMENT ET ÉLIMINATION DES CENDRES AVERTISSEMENT LAI...

Страница 36: ...oque un changement de pression suffisant pour activer l interrupteur pneumatique qui arrête l alimentation en combustible Le poêle s éteint et la mention E2 s affiche sur l écran à deux chiffres Le poêle doit s arrêter complètement avant de pouvoir être redémarré CHAMBRES INTÉRIEURES Pot de combustion Retirez et nettoyez périodiquement le pot de combustion et la zone à l intérieur du boîtier du po...

Страница 37: ...nnement du poêle elle doit être refermée dans les 30 secondes sinon le poêle s éteint Si le poêle s éteint appuyez sur l interrupteur ON OFF pour le redémarrer Le poêle doit être complètement arrêté et débranché avant de pouvoir être redémarré AVERTISSEMENT NE FAITES PAS FONCTIONNER VOTRE POÊLE AVEC LA PORTE VUE OUVERTE LA TARIÈRE N ALIMENTERA PAS DE GRANULÉS DANS CES CIRCONSTANCES ET UN PROBLÈME ...

Страница 38: ...ormances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les dégagements d installation de l appareil ou dans l espace requis pour faire le plein et enlever les cendres Cela pourrait provoquer un incendie Ne pas trop brûler ou utiliser des combustibles volatiles ou des combustibles cela pourrait causer des dommages aux personnes et à la propriété Cet appareil n est homologu...

Страница 39: ...amme entre le réglage présélectionné de la plage de chaleur désirée 1 à 5 et le réglage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne éteindra le poêle Lorsque la température ambiante souhaitée est atteinte et que le T Stat n a plus besoin de chaleur le réglage de la plage de chauffage minimale est défini sur 1 L unité ne s éteindra pas complètement Une fois que la température am...

Страница 40: ...ler la vitesse du ventilateur Quand le système de chauffage est en mode manuel le thermostat en option ne contrôlera pas correctement l unité Lorsque vous ajustez le réglage du ventilateur de tirage essayez seulement 1 réglage au dessus ou en dessous du réglage de chaleur Il est préférable de laisser le poêle en mode automatique VENTILATEUR DE LA PIÈCE Le ventilateur de la pièce s allumera une foi...

Страница 41: ...ramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage à deux chiffres des degrés Celsius aux degrés Fahrenheit et vice versa D TOUCHE mode M T Le Mode de fonctionnement du poêle peut être Manuel ou commandé par un Thermostat Des diodes distinctes à gauche de l écran à deux chiffres indiquent le mode de fonctionnement Manuel ou T stat Le poêle...

Страница 42: ...onnecteur de 6 pouces les illustrations ci dessous ne sont que des exemples Veuillez confirmer à tous les codes du bâtiment locaux ou ragulations ayant compétence avant de demander à un installateur qualifié de procéder à cette installation AVERTISSEMENT Vous voudrez peut être localiser les utilitaires ou les obstacles à l intérieur du mur avant de tenter cette installation Assurez vous de garder à ...

Страница 43: ... recommandé que l installation soit plus grand que 3 pieds 0 91 m pour obtenir au dessus de la ligne de congère Cette même installation peut être utilisée si votre chauffe eau est en dessous du niveau du sol en ajoutant simplement la section de nettoyage et tuyau vertical intérieur jusqu à ce que le niveau du sol est atteint Avec cette installation vous devez être conscient de la hauteur de la nei...

Страница 44: ...ages de chauffage et annuler votre garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez votre poêle à granulés dans un endroit qui répond aux exigences de ce manuel mais dans une zone où il ne gêne pas la charpente de la maison le câblage etc 2 Installez un tampon de foyer non combustible sous le poêle à granulés Ce coussin doit dépasser d au moins 6 po 152 mm en face de l unité 3 Placez le ...

Страница 45: ... doit comprendre un té de nettoyage pour permettre la collecte des cendres volantes et pour permettre le nettoyage périodique du système d échappement Les coudes à 90 degrés accumulent les cendres volantes et la suie réduisant ainsi le débit d échappement et les performances du poêle Chaque coude ou té réduit le potentiel de tirage de 30 à 50 Tous les joints du système de ventilation doivent être ...

Страница 46: ...ure doit être enlevée pendant le déplacement de la maison mobile Après le déplacement tous les évents doivent être réinstallés et solidement fixés L air extérieur est obligatoire pour l installation d une maison mobile Consultez la section Alimentation en air extérieur et votre revendeur pour l achat Vérifiez auprès de vos responsables locaux du bâtiment car d autres codes peuvent s appliquer EXIG...

Страница 47: ...res La protection du plancher doit s étendre sous et 2 51 mm de chaque côté du té de cheminée pour une installation verticale intérieure Les installations canadiennes nécessitent un minimum de 18 po 458 mm au delà de l avant de l appareil et de 8 po 204 mm au delà de chaque côté de l appareil po mm A Côté à poêle U S A 6 153 CAN 8 204 B De l avant au poêle U S A 6 153 CAN 18 458 DÉGAGEMENTS Votre ...

Страница 48: ...EZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON ÉLECTRIQUE SOUS DEVANT OU SUR LE POÊLE NE FAITES PAS COURIR LE CORDON ÉLECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE GÉNÈRE DU MONOXYDE DE CARBONE QUI PEUT S AVÉRER DANGEREUX POUR LA SANTÉ EN L ABSENCE D UNE VENTILATION APPROPRIÉE ATTENTION UN DÉTECTEUR DE FUMÉE FONCTIONN...

Страница 49: ...non date d inspection du système de ventilation existant _______________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et des joints de porte Confirmer les dégagements aux combustibles selon les instr...

Страница 50: ...us bas 1 9 lbs hr Taille de Pellet peut effectuer le taux réel d alimentation en carburant et de brûler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant listé pour de meilleurs résultats Temps de combustion réglage le plus bas 32 hrs approximatif Capacité de la trémie 60 lbs 27 2 kg Spécifications Électriques Note électrique 120 V 60 Hz 3 0 Amps Watts opér...

Страница 51: ...s restrictions et les exigences d installation dans votre région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entraîner des dommages matériels des blessures corporelles ou même la mort Une installation incorrecte pourrait annuler votre garantie Cons...

Отзывы: