8
CLEARANCES TO COMBUSTIBLES
It is of utmost importance that the clearances to combustible materials be strictly adhered to during
installation of the stove. Refer to the tables below :
A
C
E
F
E
B
D
Clearance To Combustibles
A
B
C
D
E
F
14” (356mm)
28” (711mm)
16” (406mm)
33” (838mm)
18” (457mm)
23” (585mm)
•
Floor to ceiling height must be at least 8’ (2.4m) in all cases.
•
Do not place any combustible material within 4’ (1.2m) of the front of the unit.
• The clearance between the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe.
•
The chimney connector must not pass through an attic or roof space, closet or similar concealed space,
a floor, or a ceiling.
• A flue pipe crossing a combustible wall must have a minimum clearance of 18” (457.2mm).
• To reduce flue clearances from combustible materials, contact your local safety department.