VG810CL SENTRY COAL™

 

VGZ-011 / 20120105.0

SAFETY INSTRUCTIONS

Read All Instructions carefully.

1.  The installation of this stove must comply with your 

local building code rulings. Please observe the clear-
ances to combustibles (see reference figures 3–5). Do 
not place fuel, furniture or any other objects within the 
clearance area.

2.  Verify that the stove is properly installed be-

fore firing the stove for the first time. After read-
ing these instructions, if you have any doubt 
about your ability to complete your installation  
properly, you must obtain the services of a  
professional licensed installer familiar with all  
aspects of safe and correct installation.  DO NOT  
use temporar y or makeshift compromises  
during installation. There must be 

NO DEVIATION OR 

ALTERATION OF ANY KIND from the very specific 
instructions spelled out in this instruction manual as 
it pertains to the installation of this woodstove.  NO 
EXCEPTIONS!

3.  DO NOT store coal, kindling, flammable liquids or 

other combustible materials in the vicinity of the ap-
pliance. Refer to certification label on back of unit and 
reference figures 3–5 in this manual.

4. 

DO NOT INSTALL THIS STOVE IN A MOBILE HOME, 
MANUFACTURED  HOME, TRAILER  OR TENT  
NO EXCEPTIONS! (HUD Federal Standard: 24 
CFR Ch.XX).

5. 

DO NOT ELEVATE THIS STOVE BY ANY MEANS. 
(i.e. bricks under legs, cement blocks)  Stove legs must 
set directly upon the solid-surface non-combustible 
floor as specified in this stove instruction manual. 

6. 

DO NOT MODIFY THIS STOVE IN ANY WAY!  
Stove must be installed with legs and bottom heat 
shield provided, attached as shown in the instruc-
tions. 

DO NOT OPERATE WITHOUT BOTTOM HEAT 

SHIELD – NO EXCEPTIONS. Heat Shield must be  
assembled and installed as shown in Assembly In-
structions. Assemble only with original parts as sup-
plied and shown in this manual. 

7. 

DO NOT OPERATE A STOVE THAT IS MISSING 
ANY PARTS!
 If any parts are missing or defective, 
please notify the dealer or manufacturer immediately. 
Replace missing, broken or worn parts with factory 
original or equivalent parts only.

8.  Do not tamper with combustion air control  

beyond normal adjustment capacities.

9.  Always connect this stove to a chimney and vent to the 

outside. Never vent to another room or inside a build-
ing. 

DO NOT CONNECT THIS UNIT TO A CHIMNEY 

FLUE SERVING ANOTHER APPLIANCE.

10. 

DO NOT CONNECT A COAL BURNING STOVE 
TO AN ALUMINUM TYPE B GAS VENT. 
This is 

not safe. Use approved masonry or an Underwriters 
Laboratories Listed UL 103 HT (USA) / ULC-S629 
(CDN) Listed Residential Type and Building Heating 
Appliance Chimney. Use a 6˝/152mm diameter chim-
ney, that is high enough to give a good draft. (See  
specifics in Chimney Connections instructions).

11.  Be sure that your chimney is safely constructed and 

in good repair. Have the chimney inspected by the fire 
department or a qualified inspector. Your insurance 
company should be able to recommend a qualified 
inspector. Chimney connector pipe must be in good 
condition. Replace if necessary before using stove.

12.  Creosote, soot or fly ash may build up in the chimney  

connector and chimney and cause a house/building 
fire. Inspect the chimney connector and chimney 
twice monthly during the heating season and clean if 
necessary. (see Service Hints section in this manual). 

13.  In the event of a chimney fire, turn the air con-

trol and flue damper to closed position, leave the 
building and 

CALL THE FIRE DEPARTMENT  

IMMEDIATELY!  Have a clearly understood plan 
on how to handle a chimney fire by contact-
ing your local fire authority for information on 
proper procedures in the event of a chimney fire.  
After the fire is out, the chimney must be cleaned 
and inspected for any stress or cracks before starting 
another fire.  Check the condition of any combustibles 
surrounding the chimney.

14. 

DISPOSAL OF ASHES Ashes should be placed in 
a steel container with a tight fitting lid and moved 
outdoors immediately. The closed container of ashes 
should be placed on a noncombustible floor or on 
the ground, well away from all combustible materials, 
pending final disposal. If the ashes are disposed of 
by burial in soil or otherwise locally dispersed, they 
should be retained in the closed container until all 
cinders have completely cooled. Other waste shall 
not be placed in this container.

15.  To prevent injury, do not allow anyone to use this 

stove who is unfamiliar with the correct operation of 
the stove.

16.  Do not operate stove while under the influence of 

drugs or alcohol.

17.  The special paints used on your stove may  

give off some smoke and an odor while  
they are curing during the first 12 to 15 fires.  Addi-
tional smoke and odor may be emitted from the light 
oils used in construction of the fire box. This should 
disappear after a short period of time and not occur 
again. Persons with lung conditions or owners of 
susceptible domestic pets (such as birds) should take  
prudent precautions. Open windows and doors as 

Содержание Sentry Coal VG810CL

Страница 1: ...S CAREFULLY BEFORE INSTALLING OR OPERATING THIS STOVE FAILURE TO FOLLOW INSTRUC TIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH NOTE IT IS RECOMMENDED INSTALLATION BE COMPLETED BY A QUALIFIED HEATING EQUIPMENT INSTALLER DO NOT INSTALL IN A MOBILE HOME REFER TO MARKINGS ON STOVE LABELS FOR ADDITIONAL INFORMATION This stove meets test standards US UL 1482 2011 CDN ULC S627 00 SAFETY ...

Страница 2: ...OVE TO AN ALUMINUM TYPE B GAS VENT This is not safe Use approved masonry or an Underwriters Laboratories Listed UL 103 HT USA ULC S629 CDN Listed Residential Type and Building Heating Appliance Chimney Use a 6 152mm diameter chim ney that is high enough to give a good draft See specifics in Chimney Connections instructions 11 Be sure that your chimney is safely constructed and in good repair Have ...

Страница 3: ...er ignition 30 DO NOT CONNECT TO OR USE IN CONJUNC TION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS 31 A COAL BURNING STOVE MUST NEVER BE IN STALLED IN A HALLWAY OR NEAR A STAIRCASE as it may block egress in the event of a fire 32 DO NOT INSTALL IN A SLEEPING ROOM DO NOT INSTALL IN AN ALCOVE OR INSIDE A FIREPLACE 33 Install at least one smoke detector on ...

Страница 4: ...CES NFPA 211 12 OPERATING INSTRUCTIONS House Fire Hazards Operating Precautions Warnings 13 Coal Types Sizes 13 Starting a Fire 13 Adding Fuel 13 Thermostat 14 SERVICE HINTS Creosote Formation Prevention Need for Removal 15 Chimney Draft 16 Door Gasket Replacement 16 PARTS SENTRY COAL STOVE 17 18 OPTIONAL F 1 BLOWER WIRING DIAGRAM 19 FLOOR PROTECTOR CALCULATIONS 20 NOTE A PROFESSIONAL LICENSED HEA...

Страница 5: ...e stove using eight 8 self tapping screws fig 1 6 Carefully lift stove to upright position 7 Locate the door knob and machine screw in the hardware pack Open the cabinet door by reaching under the cabinet frame and pulling the door open 8 Install the door knob onto the outside of the door Install the machine screw through the latch bracket door and into the knob Tighten securely fig 2 Fig 1 Leg He...

Страница 6: ...sections with three 3 sheet metal screws in each stove pipe Fig 3 Minimum Clearance Dimensions from Combustible Surfaces for USA CANADA FLOOR PROTECTOR NOTE DASHED LINES SHOW STRAIGHT OUT CHIMNEY CONNECTOR AND ADDITIONAL FLOOR PROTECTOR REQUIRED BENEATH AND EXTENDING 8 203MM ON EITHER SIDE OF CONNECTOR PIPE COMBUSTIBLE WALL CONSTRUCTION IN ACCORDANCE WITH NFPA 211 BACKWALL SIDEWALL 16 40 6cm 19 48...

Страница 7: ...FIRING STOVE SLIDE FIRE BRICKS TOWARDS THE REAR SO NO GAPS REMAIN BETWEEN BRICKS Fig 5 Top View Minimum Corner Clearances from Combustible Surfaces 18 45 7cm 18 45 7cm CORNER CLEARANCES 18 45 7cm DRAFT DAMPER 6 15cm Fig 6 Draft Damper Installation DRAFT DAMPER must be installed before use NO EXCEPTIONS Continued on next page A Draft Damper included with the stove must be installed in the first str...

Страница 8: ...the ceiling 4 The pipe cannot extend into the chimney flue figure 7 5 Secure pipe elbow sections with three sheet metal screws at each joint to make the piping rigid 6 It is recommended that no more than two 2 90 bends be used in the stovepipe installa tion The use of more than two 90 bends may decrease the amount of draw and possibly cause smoke spillage Where possible use only corrugated non adj...

Страница 9: ... held responsible for external factors leading to less than optimal drafting Should you have a problem with inadequate draft you should contact a licensed heating and cooling con tractor for assistance in solving the problem For a more in depth explanation see Chimney Draft on page 16 IMPORTANT Installation Points 1 Size chimney flue to stove collar This stove requires a minimum of a 6 152mm diame...

Страница 10: ... HVAC supply stores You may wish to view chimney manufactur ers information on line See www duravent com www selkirkinc com or www mtlfab com Venting to Existing Fireplace In some instances people desire to convert an existing fireplace for stove use Usually safe connec tion to an existing masonry chimney requires more work than using a prefabricated chimney The existing fireplace must be closed a...

Страница 11: ...od of FIG 12 Fireplace Conversion installation This is a complicated and involved process and to ensure safety should only be done by a quali fied installer 1 An entry hole must be cut through the masonry and tile liner with minimal damage to the liner At least 8 203mm of liner must remain below the entry position When locating the stove and stovepipe all minimum clearances must be observed from c...

Страница 12: ...s fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness D Chimney Section Pass through Solid insulated listed factory built chimney length with an inside diameter 2 51mm larger than the chimney connector and having 1 25 4mm or more of insulation serving as a pass through for a single wall sheet steel chimney connector of minimum 24...

Страница 13: ...o add coal to burn for longer periods of time 8 to 10 hours but doing so carelessly will promote incomplete combustion and con siderable sooting along with a very dirty inefficient fire 1 Set thermostat to HIGH and open pipe draft damper before opening the feed door to help pre vent smoke spillage CAUTION HOUSE FIRE HAZARDS GASSES EMITTED FROM FRESHLY ADDED COAL MUST BE BURNED OR THEY WILL AC CUMU...

Страница 14: ...s Fig 14 Thermostat Damper 2 Add fuel being careful not to overload or over fie the stove Never smother the fire when adding coal Incomplete combustion of fresh coal will cause gas accumulation and a mild smokey explosion will oc cur Add fresh kindling if the coal bed has cooled 3 Do not load fuel to such a height or in such a man ner that it creates a hazard when opening the door Do not add more ...

Страница 15: ...or pipe Following these steps will help reduce the rate of build up 2 Avoid smothering the fire with too much coal Too much coal loaded at one time will create heavy volitile gas which can coat the chimney with creosote forming tar 3 Burn the stove with the air inlet control wide open for 10 15 minutes every time fresh coal is loaded into the stove Do not load more than to of the fuel capacity at ...

Страница 16: ...ant flow of air is referred to as the draft Many factors or combination of factors can act together to build or impede the draft Without the correct amount of draft the stove will not operate properly If there is excessive draft an unsafe condition will arise with too much air being drawn into the stove and creating an excessively hot fire This could cause over firing which runs the risk of igniti...

Страница 17: ...Description Qty 810 12 Hinge Door 4 810 13 Back Brace 2 810 14 Thermostat Assembly 1 810 15 Chain Linkage Thermostat 1 810 16 Top Shield Thermostat 1 810 17 Screw No 10 Torx 2 810 18 Knob Thermostat 1 810 19 810 20 Support Hinge 1 810 21 Clip Hinge 1 810 1 Cabinet Top 1 810 2 Cabinet Back 1 810 3 Cabinet Left Side 1 810 4 Cabinet Front Assembly 1 810 5 Cabinet Door Frame 1 810 6 Cabinet Door 1 810...

Страница 18: ...o 10x1 2 Torque H D 2 810 37 Ash Pan Assembly 1 810 38 Damper Asm 1 810 39 Smoke Curtain 1 810 40 Bracket Smoke Curtain 1 810 41 Screw 1 4 20x3 4 Flat Head 1 810 42 Nut 1 4 20 1 810 43 Door Ash 1 810 44 Steel Liner 1 810 45 Gasket 29 Ash Door 1 Part No Description Qty 810 46 Door Asm Feed 1 810 47 Handle Separable Spring 1 810 48 Handle Door 1 810 49 Latch Door 1 810 50 Spacer 1 810 51 Screw 1 4 2...

Страница 19: ... OPTION NOTICE ANY REPLACEMENT WIRING MUST HAVE EQUIVALENT INSULATION AND TEMPERATURE RATING 105 C CAUTION MOVING PARTS CAN CAUSE INJURY DO NOT OPERATE WITH COVER REMOVED DANGER SHOCK HAZARD DISCONNECT POWER SOURCE BEFORE INSTALLATION AND WHENEVER SERVICING BLOWER ASSEMBLY ...

Страница 20: ...r a Use formulas in step 1 above to calculate R value of proposed material s b For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the floor protector system is equal to or greater than the floor protector specifications given the alternate is acceptable Definitions Thermal conductance C BTU W hr ft2 F m2 K Thermal conductivity k Btu inch W Btu h...

Страница 21: ...VGZ 011 20120105 0 VG810CL SENTRY COAL Page 21 ...

Страница 22: ...judgement when you are using this stove You are dealing with FIRE Fire is inherently dangerous and must be treated with respect Stay warm and in good health Respectfully yours Proprietor Optional F 1 Blower for Vogelzang Heat Circulator Stove Models VG820E and VG810CL For more even heat distribution the Vogelzang Heat Circulator blower draws heat from around the firebox and blows it under the stov...

Отзывы: