Page 10

 / BX42E-SN 

 

VGZ-005 / 20120202.0

Figure 12 - Chimney Construction Through Roof

Figure 13 - Chimney Connection to Firebox  

Through Masonry Wall

CHIMNEY CONNECTIONS continued …

MANUFACTURED CHIMNEY

REFER TO CHIMNEY AND CHIMNEY CONNEC-

TOR MAKER’S INSTRUCTIONS FOR INSTALLATION 
AND USE.

Use only 6” diameter listed chimney UL 103 HT. 

Chimney made to this listing is High Temperature rated 
to 2100 degrees Fahrenheit. Use chimney from only one 
manufacturer. Never mix brands. Carefully follow the 
chimney manufacturer’s stated requirements and clear-
ances. Use the chimney manufacturer’s attic guards, 
roof supports, flashing and fire stops when passing 
through a ceiling. Use a listed thimble when passing 
through a combustible wall. Do not use makeshift com-
promises during installation. 

Never use a single-wall 

connection pipe as a chimney!

When using a pre-existing chimney, have it’s condi-

tion and installation inspected before using. Make sure 
that the chimney meets all of the UL rating requirements 
listed above. Be aware that not all manufactured chim-
ney is of the UL 103 HT type.

NOTE: It is recommended that you contact a li-

censed heating and cooling contractor (consult your 
local yellow pages) for chimney installation.

Manufactured chimney with the proper required UL 

listing is available from most home centers, hardware 
stores, and HVAC supply stores.

If you have access to the internet, you may wish 

to view chimney manufacturers’ information on-line. 
See, www.duravent.com, www.selkirkinc.com, or 
www.mtlfab.com.

VENTING TO EXISTING FIREPLACE

In some instances, people desire to convert an ex-

isting fireplace for stove use. Usually, safe connection to 
an existing masonry chimney requires more work than 
using a prefabricated chimney. The existing fireplace 
must be closed and sealed at the damper with high-
temperature caulk, ceramic wool, or furnace cement. 
Prior to installation, clean and inspect the existing flue 
and smoke shelf. Installation should be designed so 
the system can be dismantled for periodic cleaning and 
inspection. Before conversion, make sure the existing 
chimney is structurally sound, the chimney incorporates 
a flue liner and make sure it is in good condition. (A flue 
liner consists of clay tile that protects the brickwork of 
a chimney. If a chimney does not have a liner, or it is 
damaged, have it relined by a professional. 

DO NOT 

USE a chimney that is unlined or damaged!) If you 
have any question regarding the condition of the chim-
ney, consult a qualified licensed contractor, qualified 
engineer, competent mason, certified Chimney Sweep, 
or a knowledgable inspector. Consult your insurance 
company if you cannot find a qualified expert.

CAUTION: Not all fireplace chimneys 
are suitable for conversion to a wood 
stove. Check with a qualified expert.

Many prefabricated fireplaces are of the “zero-

clearance fireplace” category. These consist of mul-
tilayered metal construction. They are designed with 

Chimney Minimum Height Requirements:
(1) Overall Height – 11 ft./3.35m min.
(2) Height above roof – 3 ft./91cm
(3) Height above slope – 2 ft./61cm min. within     
     10 ft./3.05m
(4) Minimum rise before horiz. section – 24 in./61cm
NOTICE: If minimum chimney requirements are 
not met, your stove will not operate properly.

Call us at 1-866-667-8454 

NorthlineExpress.com

www.NorthlineExpress.com

Содержание BX42E

Страница 1: ...save this manual for future reference NOTE THIS STOVE IS NOT A UL LISTED STOVE READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS STOVE FAILURE TO FOLLOW INSTRUC TIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH REFER TO MARKINGS ON STOVE LABELS FOR ADDITIONAL INFORMATION NOTE IT IS RECOMMENDED INSTALLATION BE COMPLETED BY A QUALIFIED HEATING EQUIPMENT INSTALLER DO N...

Страница 2: ...03 HT Residential Type and Building Heating Appliance Chimney Use a 6 152mm diameter chimney that is high enough to give a good draft See specifics in Chimney Connections instructions 10 Be sure that your chimney is safely constructed and in good repair Have the chimney inspected by the fire department or a qualified inspector Your insurance company should be able to recommend a qualified inspecto...

Страница 3: ...S 30 A WOOD BURNING STOVE MUST NEVER BE INSTALLED IN A HALLWAY OR NEAR A STAIR CASE as it may block egress in the event of a fire 31 DO NOT INSTALL IN A SLEEPING ROOM SAFETY INSTRUCTIONS continued DO NOT INSTALLTHIS UNIT IN AN ALCOVE OR INSIDE A FIREPLACE 32 Install at least one smoke detector on each floor of your home Detectors should be located away from the heating appliance to avoid false ala...

Страница 4: ...ting Precautions Warnings 12 Wood Types Sizes 12 Starting a Fire 12 Adding Fuel 13 Service Hints Creosote Formation Prevention Need for Removal 13 Stove Joints 14 Gasket Replacement 14 Parts Deluxe Boxwood 15 Floor Protector Calculations 16 Chimney Connection Systems Clearances 17 NOTE A PROFESSIONAL LICENSED HEAT ING AND COOLING CONTRACTOR MUST BE CONSULTED IF YOU HAVE QUESTIONS REGARDING THE INS...

Страница 5: ...Chimney Connection 6 black steel 24 ga min straight or elbow as required 1 2 Sheet Metal Screws Chimney Existing 6 Lined Ma sonry Chimney or 6 Inside Dia listed Type HT chimney Furnace Cement manufacturer recommends Rutland Code 78 or equivalent NOTICE Vogelzang International Corp grants no warranty stated or implied for the installation or maintenance of your wood stove and assumes no responsibil...

Страница 6: ...nd at least 18 beyond the front of the hearth to the sides and beyond the rear of the stove The area under a horizontal run of the chimney connector must also be protected extending two 2 inched beyond the outer dimension of the horizontal connector The minimum sized floor protector for this stove is 52 x 74 Consult local building codes and fire protection ordnances CAUTION FIRE HAZARD CARPETING A...

Страница 7: ...L CONTAINING COMBUSTI BLEMATERIALSUCHASWOODENSTUDSOR DRYWALLANDFACEDWITHBRICKORSTONE MUST BE CONSIDERED A COMBUSTIBLE SURFACE 6 DO NOT INSTALL THIS STOVE IN A MOBILE HOME MANUFACTURED HOME TRAILER OR TENT NO EXCEPTIONS HUD Federal Stan dard 24 CFR Ch XX Figure 7 Minimum Clearance Dimensions from Combustible Surfaces 7 The clearances provided are minimum dimensions determined by the NFPA Installati...

Страница 8: ... allow any condensation in the flue to run back into the firebox 2 Horizontal pipe runs must slope upwards towards the chimney at least 1 4 6 4mm per foot of horizontal run 3 You must have at least 18 457mm of clearance between any horizontal piping and the ceiling 4 The pipe cannot extend into the chimney flue figure 9 5 Secure pipe elbow sections with three sheet metal screws at each joint to ma...

Страница 9: ...e held responsible for external factors leading to less than optimal drafting Should you have a problem with inadequate draft you should contact a licensed heating and cooling con tractor for assistance in solving the problem IMPORTANT Installation Points 1 Size chimney flue to stove collar This stove requires a minimum of a 6 152mm diameter flue 2 Never connect this unit to a chimney serving an o...

Страница 10: ...CE In some instances people desire to convert an ex isting fireplace for stove use Usually safe connection to an existing masonry chimney requires more work than using a prefabricated chimney The existing fireplace must be closed and sealed at the damper with high temperature caulk ceramic wool or furnace cement Prior to installation clean and inspect the existing flue and smoke shelf Installation...

Страница 11: ...he masonry and tile liner with minimal damage to the liner At least 8 of liner must remain below the entry position When locating the stove and stovepipe all minimum clear ances must be observed from combustible surfaces including mantels combustible trimwork ceilings and walls Positioning the center of the stove pipe entry into the chimney 24 below the ceiling should insure proper clearance for a...

Страница 12: ...oor and secure tightly 6 Adjust the collar draft damper and door spin draft control The more closed the spin draft is set the lower and slower the fire will burn The more open the faster and hotter the fire will burn Do not over fire the stove continued on next page CAUTION HOUSE FIRE HAZARDS DO NOT STORE WOOD ON FLOOR PROTEC TOR UNDERNEATH STOVEPIPE OR ANY WHEREWITHIN MINIMUM CLEARANCES FROM COMB...

Страница 13: ...ER AND SPIN DRAFTTO RE DUCETHE AIR SUPPLY AND SLOW DOWNTHE FIRE TOO MUCH WOOD OR BURNING NON RECOMMENDED MATERIALS SUCH AS TRASH OR FLAMMABLE LIQUIDS MAY CAUSE OVER FIRING continued on next page CAUTION DO NOT OVER FIRE APPLIANCE CAUTION SLOW BURNING FIRES AND EX TENDED USE MAY CAUSE EXCESSIVE CREO SOTE BUILDUP IGNITION OF CREOSOTE BUILDUP OR OVERFIRING MAY CAUSE A CHIMNEY FIRE CHIMNEY FIRES BURN ...

Страница 14: ...buildup of condensation or creosote in the chimney are warnings that the chimney is NOT functioning properly Correct the problem before using the stove Following are some possible causes for improper draft 1 The connector stovepipe may be pushed into the chimney too far stopping the draft 2 If the chimney temperature is too cool water will condense in the chimney and run back into the stove Creoso...

Страница 15: ... parts Part No Description Qty 42 01 Leg 4 42 02 Bottom 1 42 03 Side 2 42 04 Back 1 42 05 Front 1 42 06 Door 1 42 07 Top 1 42 08 Damper Slide Draft 1 42 09 Lid 2 42 10 Lid Support 1 42 11 Hearth 1 42 12 Damper Collar Assembly 1 42 13 Handle Assembly 1 42 14 Lid Lifter L 1 1 42 15 42 16 S Hook used to hang lid lifter 1 42 17 Spin Draft 1 42 18 Door Latch 1 42 19 Gasket Door 1 4 dia fiberglass 1 HP ...

Страница 16: ...late R value of proposed material s b For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the floor protector system is equal to or greater than the floor protector specifications given the alternate is acceptable Definitions Thermal conductance C BTU W hr ft2 F m2 K Thermal conductivity k Btu inch W Btu hr ft2 F m K hr ft F Thermal resistance R ...

Страница 17: ...52mm of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness D Chimney Section Pass through Solid insulated listed factory built chimney length with an inside diameter 2 51mm larger than the chimney connector and having 1 25 4mm or more of insulation serving as a pass through for a single wall sheet steel chimney connector o...

Страница 18: ...d health Respectfully yours Proprietor COMPANY TESTIMONY Vogelzang International Corporation 400 West 17th Street Holland Michigan 49423 www vogelzang com Phone 1 616 396 1911 Fax 1 616 396 1971 FOR GOD SO LOVED THE WORLD THAT HE GAVE HIS ONLY BEGOTTEN SON THAT WHOEVER BELIEVES IN HIM SHALL NOT PERISH BUT HAVE ETERNAL LIFE JOHN 3 16 MADE IN CHINA SteveVogelzang DO NOT USE THIS STOVE IN A MOBILE HO...

Отзывы: