ChImNEY CONNECTIONS continued …

e n d o r s e m e n t s   f r o m   n a t i o n a l l y   r e c o g n i ze d  
organizations for use as fireplaces, they have not been 
tested for connection to wood stove heaters. Connecting 
a stove to such a device will void the manufacturer’s 
warranty.

Venting a stove directly into a fireplace does not 

meet code and should not be attempted. The stove war-
ranty will be void with such an installation. Do not create 
a hazard in your home by connecting in this manner.

FIREPLACE INSTALLATION

NOTE: DO NOT ATTEmPT TO ROUTE THE CHIm-

NEY CONNECTOR PIPE THROUGH THE THROAT OF 
THE FIREPLACE. 
Directly connecting the stovepipe 
into the existing masonry chimney (figure 11 “Type A” 
Fireplace Conversion) of the fireplace is the ONLY ap-
proved method of installation. If the chimney is behind a 
combustible wall, you must use an approved wall pass-
through system to gain access to the chimney. This is a 
complicated and involved process and to ensure safety 
should only be done by a qualified installer.
1.  An entry hole must be cut through the masonry and 

tile liner with minimal damage to the liner. At least 8” 
of liner must remain below the entry position. When 
locating the stove and stovepipe, all minimum clear-
ances must be observed from combustible surfaces 
including mantels, combustible trim work, ceilings 
and walls. Positioning the center of the stove pipe 
entry into the chimney 24˝ below the ceiling should 
insure proper clearance for a 6˝ stovepipe.

2.  Install a fire clay (5/8˝ minimum thickness) thimble. 

Make sure the thimble is flush with the inner surface 
of the chimney liner and does not protrude into the 
flue (see figure 8 on page 6).

Fig. 11 - Fireplace Conversion

3.  Secure the thimble with refractory mortar. The 

thimble should be surrounded by 12˝ of solid unit  
masonry brickwork or 24˝ of stone.

4.  Install the stovepipe into the thimble as far as pos-

sible without extending past the flue lining (see 
figures 6 & 7 on pages 6 & 7).

5.  A small airspace (about 1/2˝) should remain 

between the stovepipe and thimble to allow for 
expansion of the pipe. Seal this airspace with high-
temperature caulking or ceramic wool.

6.  Secure and seal the damper in the closed posi-

tion using high-temp caulking, ceramic wool, or 
furnace cement. Also check to see if the chimney 
has a cleanout. If it does, make sure it is closed and 
sealed as well. A leaky cleanout will greatly reduce 
draft efficiency.

If you have any questions regarding venting your 

stove, contact the manufacturer or contact the Na-
tional Fire Protection Association (NFPA) and request 
a copy of the latest editions of NFPA Standard 211 
and NFPA Standard 908. Their address is:

 Battery March Park, Quincy, MA 02269.

Содержание BK150E

Страница 1: ... 17th Street Holland Michigan 49423 www vogelzang com Phone 1 616 396 1911 Fax 1 616 396 1971 Deluxe BARREL stove KIT Model BK150E Owners Manual save this manual for future reference Do NOT install this stove in a mobile home Manufactured Home tent or trailer NO EXCEPTIONS NOTE This stove is NOT a UL listed stove NOTE A professional licensed heat ing and cooling contractor should be consulted if y...

Страница 2: ...ve to a chimney and vent the outside Never vent to another room or in side a building DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE 10 Do NOT connect a Wood burning stove to an aluminum Type B gas vent This is not safe Use approved masonry or an Underwriters Laborato ries Listed UL 103 HT Residential Type and Building Heating Appliance Chimney Use a 6 152mm diameter chimney ...

Страница 3: ... discoloration will occur if the stove is over fired 19 Clean stove frequently as soot creosote and ash may accumulate 20 Alert all persons to the hazards of high surfacetemperatures while stove is in operation especially young children Keep away from a hot stove to avoid burns or clothing ignition 21 DO NOT leave small children unsupervised when they are in the same room as the stove If small chi...

Страница 4: ...otection Install on non combustible soil or con crete floor Non combustible floor protection must be pro vided under any connector pipe extending 2 on either side Chimney Connector Pipe round 6 dia minimum 24 MSG black or 26 MSG blue steel stove pipe straight and or elbow s as required 1 2 Sheet Metal Screws Chimney Existing 6 Lined Ma sonry Chimney or 6 Inside Dia listed Type HT chimney Furnace C...

Страница 5: ...ll stove pipe elbows and thimble as required utilizing either a recently cleaned and inspected code approved 6 masonry chimney with flue liner or a 6 i d maximum 64 square inch listed chimney 4 Use 6 round black stove pipe Do Not use gal vanized pipe Secure pipe sections with three 3 sheet metal screws in each stove pipe and or elbow joint to firmly hold the pipe sections together Screws should be...

Страница 6: ...ey flue figure 6 5 Secure pipe elbow sections with three sheet metal screws at each joint to make the piping rigid Screws should be spaced no more than a maximum of 3 76mm apart 6 It is recommended that no more than two 2 90 bends be used in the stovepipe installa tion The use of more than two 90 bends may decrease the amount of draw and possibly cause smoke spillage Where possible use only corrug...

Страница 7: ...y available at stove stores and are economi cal to rent or purchase Factors such as wind barometric pressure trees terrain and chimney temperature can have an adverse effect on the draft The manufacturer cannot be held responsible for external factors leading to less than optimal drafting Should you have a problem with inadequate draft you should contact a licensed heating and cooling contractor f...

Страница 8: ... chimney manufacturers information on line See www duravent com www selkirkinc com or www mtlfab com Venting to Existing Fireplace In some instances people desire to convert an ex isting fireplace for stove use Usually safe connection to an existing masonry chimney requires more work than using a prefabricated chimney The existing fireplace must be closed and sealed at the damper with high tempera...

Страница 9: ...nces must be observed from combustible surfaces including mantels combustible trim work ceilings and walls Positioning the center of the stove pipe entry into the chimney 24 below the ceiling should insure proper clearance for a 6 stovepipe 2 Install a fire clay 5 8 minimum thickness thimble Make sure the thimble is flush with the inner surface of the chimney liner and does not protrude into the f...

Страница 10: ...ess having two 1 25 4mm air channels separated from combustibles by a minimum of 6 152mm of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness D Chimney Section Pass through Solid insulated listed factory built chimney length with an inside diameter 2 51mm larger than the chimney connec tor and having 1 25 4mm or more of i...

Страница 11: ...7 NEVER build extremely large fires in this type of barrel stove as damage to the barrel stove or smok ing may result 8 If you have too much draft then regulate the draft with the 6 cast iron stove pipe damper in the damper collar 9 DO NOT TOUCH the barrel stove after firing until it has cooled continued on next page CAUTION HOUSE FIRE HAZARDS Do not store wood on floor protec tor underneath stove...

Страница 12: ...on Inspect stove and pipe every 60 days Replace immediately if stovepipe is rusting or leaking smoke into the room CAUTION Slow burning fires and ex tended use may cause excessive creo sote buildup Ignition of creosote buildup or over firing may cause a chimney fire Chimney fires burn ex tremely hot and may ignite surround ing materials In case of a chimney fire immediately LEAVE THE BUILDING AND ...

Страница 13: ...pected by a qualified expert before using again ASH DISPOSAL Do not allow ashes to accumu late higher than the optional grate Dispose of properly See Safety Instructions 14 page 2 Chimney Draft Draft is a function of the chim ney not the stove do not expect the stove to draw Smoke spillage into the house or excessive buildup of condensation or creosote in the chimney are warnings that the chimney ...

Страница 14: ...parts list provided to identify parts Contact us at 616 396 1911 to order parts Ref Part No No Description Qty 1 DC100 Damper Collar 1 2 150 2 Leg Assembly 2 3 150 3 Door Pin 2 4 150 4 Door Latch 1 5 150 5 Cool Touch Ball Knob 1 6 150 6 Door Bracket 1 7 150 7 Hardware Bag 1 11 150 11 Door Frame 1 12 150 12 Door 1 13 GK 14 Door Gasket 1 14 GK 14 Spin Dial Door Gasket 1 15 150 15 Spin Dial 2 16 150 ...

Страница 15: ...vice performed by description The chimney connector and chimney should be inspected at the beginning of and at least twice a month during the heating season to determine if a creosote buildup has occurred Use this chart to record inspection maintenance service to help schedule necessary service ...

Страница 16: ...and must be treated with respect Stay warm and in good health Respectfully yours Proprietor Vogelzang International Corporation 400 West 17th Street Holland Michigan 49423 www vogelzang com Phone 1 616 396 1911 Fax 1 616 396 1971 Company Testimony For God so loved the world that he gave his only begotten Son that whoever believes in Him shall not perish but have eternal life John 3 16 MADE IN CHIN...

Отзывы: