Asse mbl y
30
WBV.PU.002.EN VX186QD V2.0
6.5.4
Coupling guard
WARNING
Injuries caused by friction, catching, abrasion from the exposed rotating coupling!
During start-up and operation of the machine, the rotating coupling may be touched accidentally.
The coupling must be completely covered by a coupling guard.
•
The machine may only be started up again after maintenance, repairs or troubleshooting once all the
protective equipment has been re-installed.
•
Check the fixed screw connection of the coupling guard after the first 20 operating hours and then
every 2000 operating hours (at least once a year).
Fig. 12: Coupling guard
Pos. Quantity Part no.
Denomination
Tightening torque
1
2
GZS0338
Coupling guard, individual part
2
1
GZS0334
Separation mat
3
1
GZS0336
Safety plate
4
6*
NSI.086
M 6 x 25 cylinder head bolt
2 Nm
5
6*
NMK.003
M 6 hexagon nut
6
4
NSK.027
M 10 x 25 hexagon head bolt
50 Nm
* With length (L) of coupling guard < 383 mm: 4 pcs.