2.7. System settings: Box ID, RS232, Ethernet
➢
Box ID, RS232 and Ethernet settings shall be executed through CH-1. The setting result will be
applied to complete unit. It can be changed through OSD menu, WebGui or PC Tool.
➢
Default IP address is 192.168.0.100.
➢
When multiple units are used at the same time, user can set different IP address in each UD100 so
that each UD100 can be controlled independently.
➢
For multiple channel operation, user can select channel directly for further operation. It is nothing
to do with Box ID and IP address.
2.7.1. Box ID
➢
The range of Box ID is 0 ~ 99 for RS232 command.
➢
If user uses remote controller to execute individual box operation, the Box ID range is 0 ~ 9.
2.7.2. RS232 settings
➢
RS232 is designed with DB-9 connector. User can select baud rate between 11520 and 9600.
➢
UART protocol for the control from RS-232 or Ethernet is available in the website.
2.7.3. Ethernet
➢
User needs to connect GeoBox to WiFi Router or switch/hub through RJ45 to LAN port. Then user
can control the system through Ethernet.
➢
Crossover UTP cable can be used for direct connection between PC and GeoBox. User needs to
set PC TCP/IPv4 with the same domain segment as GeoBox (for instance, to set IP address at
192.168.0.105) and subnet mask at 255.255.255.0). In some PC, normal UTP cable can be used.