![VMC VW-330-CW Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/vmc/vw-330-cw/vw-330-cw_instruction-manual_1043152002.webp)
A/D value.
4.
Place the full weight (eg.15kg forVW-15kg) on platform. After the
stable A/D value is displayed, and then press
[ZERO]
, the display will
show "00SAVE" and now calibration is finished.
Return to weighing mode
Power off. Take off the short circuit connector plug (jumper) at the board
and plug in 1
、
2 socket , then place the scale on a flat, stable surface,
turn the power on,
all display segments will appear on the LCD a few
seconds and finally “0” will appear on the display. The scale is now in
weighing mode. Place full weight(eg.15kg forVW-15kg) on the platform
to make sure that weighing is correct, if not, repeat steps 2-4.
Ⅴ
.REMARK
1. Place the scale horizontally and keep the bubble inside of bubble
level aligned with the red circle.
2. When the recharging sign“
” turn on, please charge the battery
immediately, the time of charging is about eight to ten hours.
3. You must use the charger (adapter) supplied with the scale.
4. If after recharging and the battery does not last long, replace with
new battery.
5. For power saving, please turn off the back-light. Please turn off the
power when not in use.
VW-330-CW CHECK WEIGHER MANUAL
Ⅰ
. Power on:
Place the scale horizontally and keep the bubble inside the bubble
level aligned with the red circle (See Fig.1).
Correct Incorrect
Fig.1
Ⅱ
. Function explanation:
1. WEIGHT
DISPLAY indicates the net weight on the platter.
2. TARE
WEIGHT
DISPLAY indicates the preset tare weight.
3. GROSS WEIGHT
DISPLAY indicates the gross weight on the
platter.
4. LOW
indicator turns on with alarm when the weight is under the
user defined LOW Limit.
5. HIGH
indicator turns on with alarm when the weight exceeds the
user defined HIGH Limit.
6. CHECK WT
indicator turns on when the scale is set to [CH=1]
check weighing mode.
7. WT
indicator turns on when the scale is set to [CH=2] weighing
mode.
8. LOW BAT
Indicator turns on when battery voltage is lower then
normal operate voltage.
9. M+
DISPLAY indicate the times and the weight for accumulation,
and could be accumulation up to 99 counts.
10. TOTAL
DISPLAY indicates the accumulated total weight.
11. ZERO
KEY set readjust the scale in correct zero position for
accurate weighing operation, zero range is 4%.
4
1