VMAC
– Vehicle Mounted Air Compressors
Toll Free:
1-888-241-2289 Local: 250-740-3200
Fax: 1-250-740-3201
13
The unit must be level or must not exceed 35°, as higher angles will
affect lubrication and oil and air separation.
Never start the engine before the compressor system has fully
depressurized. Starting or restarting the engine with pressure in the
system causes extremely high loads on the internal components and
may cause premature failure that may void any warranty claims.
2.2.1 Make sure the air operated equipment is securely connected to
the supply valve and turned OFF.
If air operated equipment is faulty, not securely
connected, or not connected then excessive oil may be
noticed in discharge air.
2.2.2 Place the engine main RUN-STOP switch in the STOP
position.
2.2.3 Place the compressor ON-OFF switch in the OFF position.
2.2.4 Turn the air supply valve OFF.
2.2.5 Perform the “Before Start Up” checks in procedure 2.1.
2.2.6 Start the engine according to the equipment starting procedure.
2.2.7 Turn the compressor ON-OFF switch to the ON position.
2.2.8 Slowly open the supply valve. The compressor will supply
compressed air as demand requires.
2.3 Shutdown Procedure
2.3.1 Turn OFF the air equipment connected to the supply valve.
2.3.2 Close the supply valve.
2.3.3 Turn the compressor ON-OFF switch to the OFF position.
2.3.4 Shutdown the engine according to the equipment instructions.