RAPTAIR-MF Error Codes and Symptoms 

 

Document 

Version 

Department 

Revision Details 

Revised by 

Tech 

Engineering 

Implemented 

EXT-MF-015 

Tech 

Update Systems affected 

MSP 

N/A 

N/A 

25 June 2018 

 

Page 

1

 of 

7

 

Knowledge Base

www.kb.vmacair.com

 

Email

[email protected] 

Web: 

www.vmacair.com

  

Technical Support: 

1(888)241-2289

  

Toll Free:

1(800)738-8622

  Fax: 1(877)740-3202 

 

System or Parts affected

  

 

 

Multifunction Power Systems 

 

Index 

 

System or Parts affected ............................................................. 1

 

Overview ....................................................................................... 1

 

Entering DIAGNOSTIC MODE to Retrieve Logged Errors ....... 1

 

Error Message Table .................................................................... 3

 

Warning Message Table ........................................................... 4

 

Modifying System Parameters .................................................... 6

 

Factory Reset ............................................................................ 6

 

 

Overview

   

 

A quick reference for error codes, symptoms, trouble shooting and wire diagrams. 

 

If an error is present, the RAPTAIR MF unit WILL NOT start the compressor until the error 
is cleared. When an error is present the WARNING LED will flash on/off and the screen will 
display ‘ERRORS DETECTED’ followed by the following list of errors. The user MUST 

scroll through ALL the displayed errors by pressing the NEXT button before the unit can 
re-try the start sequence. 

 

Entering DIAGNOSTIC MODE to Retrieve Logged Errors

   

 

1)  Key on the system but do not start. No error messages on the display box should be shown. 
2) 

Press the “NEXT” and “BACK” buttons for 5 seconds to enter Diagnostics Mode. 

3) 

Press the “NEXT” and “BACK” buttons to scroll to “VIEW LOGGED ERRORS”. 

4) 

Press the “ON/ENTER” button to view the errors. 

5) 

Use “NEXT” and “BACK” to scroll through the errors. Fill in all of the blank boxes on the following 
table. 

 

The tables below represent the lines that will be shown on the control box display. Completely fill in all of 

the blanks on the following tables. (Figure 1 provides an example of an error message)  

 

  Figure 1 

 

 

Содержание RAPTAIR-MF

Страница 1: ...NOT start the compressor until the error is cleared When an error is present the WARNING LED will flash on off and the screen will display ERRORS DETECTED followed by the following list of errors The...

Страница 2: ...888 241 2289 Toll Free 1 800 738 8622 Fax 1 877 740 3202 Name __________________________ Phone ______________________ Company _______________________ Email Fax ____________________ Date _____________...

Страница 3: ...ity of a plug 12 AIR PRESS SIGNAL VOLTAGE LOW Low voltage reading on the air pressure transducer 13 AIR PRESS SIGNAL VOLTAGE HIGH Low voltage reading on the air pressure transducer 14 AIR PRESS SIGNAL...

Страница 4: ...E TOO LOW The battery voltage is below threshold for 5 seconds see Section 7 7 for threshold adjustment 46 ENGINE RESTART DUE TO COLD The engine has auto restarted due to the low internal temperature...

Страница 5: ...ature shut down Frequent over temperature shut down Low oil level Check oil level with equipment on level ground Restricted oil lines Check for kinked or pinched lines Plugged oil filter Replace oil f...

Страница 6: ...able parameters will reset to factory settings Pressing ENTER on this screen will display CANCEL Pressing NEXT will show CONFIRM RESET Pressing BACK will display CANCEL again Select the desired option...

Страница 7: ...8 8622 Fax 1 877 740 3202 Setting Description Adjustment Default Allow Low Battery Restart In Standby allow the engine to restart based on low battery level Enabled Disabled Enabled Battery Restart Lo...

Отзывы: