Error Message Table

 

 

Error 
Code 

Error Message Displayed 

Cause 

COMP TEMP SENSOR 

FAILED 

– OPEN 

Temperature sensor on the compressor is unplugged 
or wire to control box has been cut. 

COMP TEMP SENSOR 

FAILED 

– SHORT 

Temperature sensor on the compressor is shorted. 

COMP TOO COLD  

xx.x F/xx.x C 

Compressor is too cold to start. The temperature is 
displayed. 

COMP OVER TEMP  

xx.x F/xx.x C 

Compressor is too hot to start. The temperature is 
displayed. 

MANIFOLD TEMP  

FAILED 

– OPEN 

Temperature sensor on the manifold is unplugged or 
wire to control box has been cut. 

10 

MANIFOLD TEMP  

FAILED 

– SHORT 

Temperature sensor on the manifold is shorted. 

11 

MANIFOLD ERROR  

CHECK COALESCER 

The coalescer should be checked. There is a 
possibility of a plug. 

12 

AIR PRESS SIGNAL 

VOLTAGE LOW 

Low voltage reading on the air pressure transducer. 

13 

AIR PRESS SIGNAL 

VOLTAGE HIGH 

Low voltage reading on the air pressure transducer. 

14 

AIR PRESS SIGNAL 

VOLTAGE HIGH 

Air pressure is too high to start the engine. 

AIR PRESSURE 

 xxx.x PSI 

If the previous error is present the air pressure is 
displayed. 

34 

ENGINE RPM  

NOT DETECTED 

Engine RPM is not detected. Wire may be cut, tach 
sensor on bell-housing may be loose or fuel problem 
caused engine to stop suddenly. 

35 

ENGINE CRANK  

TIME OUT 

The engine did not start during the crank cycle. 

36 

ENGINE OIL LOW 

Oil level in the diesel engine is low. 

37 

ENGINE TEMP  

PROBE OPEN 

Temperature sensor on the diesel engine is 
unplugged or wire to control box has been cut. 

38 

ENGINE TEMP  

PROBE SHORT 

Temperature sensor on the diesel engine is shorted. 

39 

ENGINE TEMP TOO  

COLD TO START 

The diesel engine is too cold to start. 

40 

ENGINE OVER TEMP 

The diesel engine is too hot to start. 

41 

SERVICE PANEL 

 

OPEN The service panel is open. It must be closed before 
the unit is run. 

 

42 

FUEL LEVEL LOW  

PLEASE RE-FILL 

Fuel level for the diesel engine is low. It must be re-
filled before the unit is run. 

27 

UNEXPECTED ENGINE 

OPERATION 

Unexpected engine operation can have many 
causes. It is likely due to RPM detected during an 
OFF state. 

Содержание RAPTAIR-MF

Страница 1: ...NOT start the compressor until the error is cleared When an error is present the WARNING LED will flash on off and the screen will display ERRORS DETECTED followed by the following list of errors The...

Страница 2: ...888 241 2289 Toll Free 1 800 738 8622 Fax 1 877 740 3202 Name __________________________ Phone ______________________ Company _______________________ Email Fax ____________________ Date _____________...

Страница 3: ...ity of a plug 12 AIR PRESS SIGNAL VOLTAGE LOW Low voltage reading on the air pressure transducer 13 AIR PRESS SIGNAL VOLTAGE HIGH Low voltage reading on the air pressure transducer 14 AIR PRESS SIGNAL...

Страница 4: ...E TOO LOW The battery voltage is below threshold for 5 seconds see Section 7 7 for threshold adjustment 46 ENGINE RESTART DUE TO COLD The engine has auto restarted due to the low internal temperature...

Страница 5: ...ature shut down Frequent over temperature shut down Low oil level Check oil level with equipment on level ground Restricted oil lines Check for kinked or pinched lines Plugged oil filter Replace oil f...

Страница 6: ...able parameters will reset to factory settings Pressing ENTER on this screen will display CANCEL Pressing NEXT will show CONFIRM RESET Pressing BACK will display CANCEL again Select the desired option...

Страница 7: ...8 8622 Fax 1 877 740 3202 Setting Description Adjustment Default Allow Low Battery Restart In Standby allow the engine to restart based on low battery level Enabled Disabled Enabled Battery Restart Lo...