PREDATAIR Error Codes and Symptoms 

 

Document 

Version 

Department 

Revision Details 

Revised by 

Tech 

Engineering 

Implemented 

EXT-PRED-016 

Tech 

Document Release 

SP 18 Aug 2015 

DB 18 Aug 2015 

N/A 

18 Aug 2015 

 

Page 

5

 of 

8

 

Knowledge Base

www.kb.vmacair.com

 

Email

[email protected] 

Web: 

www.vmacair.com

  

Technical Support: 

1(888)241-2289

  

Toll Free:

1(800)738-8622

  Fax: 1(877)740-3202 

 

or problem with 
wiring connections 
Pressure sensor has 
failed or problem 
with wiring 
connections 

Check pressure sensor and wiring. 

Low system air pressure.  

Air reservoir drain 
open.  

Close valve. 

Air leak. 

Check all fittings. Check air lines for 
wear/damage. 

System demands 
exceed compressor 
delivery. 

Reduce air demand. Check for correct amount 
of hydraulic flow for the desired CFM. 

Blowdown system 
stuck.  

Check for air venting from blowdown cap while 
running. 

Compressor stalling/not 
building air. 

Hydraulic relief valve 
lifting. 

Check hydraulic pressure while running. Check 
for other relief valves in system set too low. 
Minimum setting 2800psi. 

Hydraulic flow too 
low. 

Check for correct amount of hydraulic flow for 
the desired CFM. Ensure that engine rpm is 
being maintained when load is applied. 

Unload Solenoid 
Failure 

Check solenoid and wiring. 

 

General 

Message/Problem 

Possible Causes 

Corrective Action 

CHECK AIR 
FILTER 

Every 100 hrs, the system 
reminds the operator to 
check the air filter. 

Check air filter and replace as needed. 
Message will stop automatically after 6 
hrs of operation. 

HRS:XXXX:XX 
500S 

Every 500 hrs, the system 
reminds the operator to 
service the compressor. 

Perform service as per Owner’s manual 
using VMAC service kit. Once complete, 
enter the Diagnostics Mode and clear 
the service reminder. Refer to the 
app

ropriate section in the Owner’s 

manual. 

OVER TEMP 
COMP - 
Compressor is 
getting too hot and 
is shutting down. 

Low compressor oil.  

Check oil level and fill as required. 

Oil flow restricted. 

Check oil filter for blockage. Remove 
hoses and check for blockage. Check 
cooler for blockage 

Fan not operating. 

Check connections. Check fan and relay 

Insufficient air-flow or 
ventilation. 

Make sure the cooler and air filter are 
not blocked. Open door if installed in a 
cabinet. Improve ventilation. Move the 
PREDATAIR out of the cabinet. 

Failed temperature probe 
or bad wiring connection. 

Check the temperature probe and wiring 
connections. 

Содержание AIR INNOVATED H400001

Страница 1: ...oting 7 Temporarily override the compressor temperature sensor 7 Temporarily override the hydraulic temperature sensor 7 Electrical Schematic 8 Overview General error codes symptoms and trouble shooti...

Страница 2: ...______________________ Company _______________________ Email Fax ____________________ Date ________________ Error Code Error 1 Compressor has Over Temped 138C 2 Hydraulic has Over Temped 88C 3 Not Use...

Страница 3: ...On Steady Off Operating None Off On Steady Compressor Off Fan On Compressor Too Hot Off Flashes On Off continuously Compressor Off Fan On Hydraulic Oil Too Hot One Flash Pause One Flash continuously...

Страница 4: ...rting the PTO system The Cold Climate Kit A700146 can be installed to speed warm up once the hydraulic oil temperature has reached 13oF 25oC HYD OIL WARMING HYD XXXF XXXC The hydraulic oil is between...

Страница 5: ...correct amount of hydraulic flow for the desired CFM Ensure that engine rpm is being maintained when load is applied Unload Solenoid Failure Check solenoid and wiring General Message Problem Possible...

Страница 6: ...r or bad wiring connection Check the pressure sensor and wiring connections CONNECTION ERR Failed control box display box or bad wiring connection Failed control box display box or bad wiring connecti...

Страница 7: ...probe is disabled you need to back out of the DIAGNOSTIC screen by pressing both the ON and OFF buttons simultaneously You will need to do this twice to back right out to the main screen To reset the...

Страница 8: ...d by Tech Engineering Implemented EXT PRED 016 A Tech Document Release SP 18 Aug 2015 DB 18 Aug 2015 N A 18 Aug 2015 Page 8 of 8 Knowledge Base www kb vmacair com Email tech vmacair com Web www vmacai...

Отзывы: