ViziT BUD-420M Скачать руководство пользователя страница 6

1

2

3

8 7 6 5 4

1

2

3

8 7 6 5 4

1

2

3

8 7 6 5 4

Doorstation

-431DXKCB

(

-432RCB)

BVD

BVD

8

7

6

5

4

3

2

1

VO
VG

TM

SP+

SP-

MIC

GND

+E

DSD

CUD

8

7

6

5

4

3

2

1

VO
VG

TM

SP+

SP-

MIC

GND

+E

DSD

CUD

8

7

6

5

4

3

2

1

VO
VG

TM

SP+

SP-

MIC

GND

+E

DSD

CUD

50 V

1 A

LINE

GND

SEL1

Ek

USE

Evk

GND

GND

SEL0

+DL

-DL

OP

TM

SP+

SP-

MIC

GND

+E

DSD

CUD

ML

EL

LOCK

LINE

GND

SEL1

Ek

USE

Evk

GND

GND

SEL0

+DL

-DL

OP

TM

SP+

SP-

MIC

GND

+E

DSD

CUD

ML

EL

LOCK

LINE

GND

SEL1

Ek

USE

Evk

GND

GND

SEL0

+DL

-DL

OP

TM

SP+

SP-

MIC

GND

+E

DSD

CUD

ML

EL

LOCK

Electromagnetic

lock

VIZIT-ML400

Button

EXIT 300М

Red

Green

Blue

White

Black

To commutators

Control Unit

BUD-420M

Figure 1 - Control Unit

and button

BUD-420M

BVD-431DXKCB(

-432RCB)

VIZIT-ML400

“EXIT 300М”

with doorstation

,

electromagnetic lock

BVD

Electromagnetic

lock

VIZIT-ML400

To commutators

Control Unit

BUD-420M

Button

for exit

Figure 2 - Control Unit

and button for exit

BUD-420M

BVD-431DXKCB(

-432RCB)

VIZIT-ML400

with doorstation

,

electromagnetic lock

BVD

E

LECTROMECHANICAL

LOCK

,

)

(

12V 1A

To commutators

Control Unit

BUD-420M

Figure 3 - Control Unit

BUD-420M

BVD-431DXKCB(

-432RCB)

with doorstation

and electromechanical lock

BVD

To commutators

To commutators

To commutators

Doorstation

-431DXKCB

(

-432RCB)

BVD

BVD

Doorstation

-431DXKCB

(

-432RCB)

BVD

BVD

EXAMPLES OF WIRING DIAGRAMS

6

Содержание BUD-420M

Страница 1: ...ic shock do not make any repair when the power is on The mains plug shall remain readily operable No metallic objects shall penetrate into ventilation openings of the unit The unit shall not be expose...

Страница 2: ...cess code by dialing a 3 digit individual access code Programmable unlocked state duration or seconds Key memorizing by a continuous register up to keys or by the apartment list clusters of up to keys...

Страница 3: ...ommutators to be used depend on number of subscribers and type of subscriber devices Adoorphone video doorphone may include such commutators as Commutators Where a video doorphone uses commutators the...

Страница 4: ...l Unit via terminals on its PCB To perform connections remove the lid from the Control Unit Terminals names and destinations to connect a doorstation button EXIT EXIT and lock are given below inTable...

Страница 5: ...tween the and terminals of that commutator or distribution amplifier which goes last in the video circuit see Fig 4 Examples of wiring diagrams of the Control Unit and various commutators distribution...

Страница 6: ...Button EXIT 300 Red Green Blue White Black To commutators Control Unit BUD 420M Figure 1 Control Unit and button BUD 420M BVD 431DXKCB 432RCB VIZIT ML400 EXIT 300 with doorstation electromagnetic lock...

Страница 7: ...the last BK To monitors in apartments LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 VIZIT M430C Monitor Power Supply Unit Commutator V BK M 18V 18V V1 FA LN VG V2 FB LN VG V3 FC LN VG GND LINE SEL Ek VI VG VG...

Страница 8: ...A Ec1 Ec2 GND VI2 Commutator 440 BKM VIZIT M430C Monitor LN GND LN E VI AWAY REC MENU To next commutator BK MV 4 4 3 2 1 1 2 3 4 LINE GND SEL1 Ek USE Evk GND GND SEL0 1 2 3 4 6 7 5 1 2 3 4 6 7 Apartme...

Страница 9: ...mplifier RVS 4 Apartment Handset UKP 12 M 12 M Apartment Handset UKP To power supply unit To power supply unit LN FD LN FC V4 VG VG V1 VG V1 V4 VG LN FC LN FD FA FB LN FA LN FB 82 and terminals of the...

Страница 10: ...08 82 and terminals of the last Ohms resistor shall be connected between in the circuit VO VG RVS 4 See Fig 1 3 Control Unit BUD 420M Doorstation 431DXKCB 432RCB BVD BVD 12 M UKP 12 M UKP 12 M UKP 12...

Страница 11: ...1 E8 E4 E5 E1 E0 E2 E6 E7 E3 E9 GND LINE SEL Ek DA DA DB DC DB DC 9 4 8 3 7 6 1 2 0 5 E8 E4 E5 E1 E0 E2 E6 E7 E3 E9 DB DA Commutator 30 BK M V1 VG V2 V3 VG V4 DC See Fig 1 3 Control Unit BUD 420M Doo...

Страница 12: ...istribution Amplifier RVS VIZIT M430C 12 M UKP VIZIT M430C VIZIT M430C VIZIT M430C 12 M UKP 12 M UKP 12 M UKP 12 M UKP 12 M UKP To apartments with hundred even The terminal of commutators connecting a...

Страница 13: ...G VG VG1 VI2 VO2 VO VO1 VI1 USE Evk GND Entrance 2 1 3 2 1 1 2 3 4 6 7 5 To commutators Commutator BK 2V To the terminal of Control Unit No 2 E 3 1 2 3 4 5 1 2 3 4 5 6 7 SWITCHES Priority B 1 2 ON SWI...

Страница 14: ...x KC 101 Concierge Terminal VIZIT TK401D DM 1 2 3 4 5 1 2 3 4 5 6 7 INT 15V GND DATA LN IN Ek LN OUT OP SEL1 SEL0 GND LN E Ec GND 1 2 3 4 1 2 3 4 5 2 3 4 5 1 6 7 6 7 Concierge Control Unit VIZIT TU412...

Страница 15: ...ccess code enables or disables individual access codes enables or disables key memorizing by subscribers sets unlocked state duration OFF second ON seconds enables or disables a beep in the apartment...

Страница 16: ...r a 4 digit password If the password is correct a beep is sounding You are now in the Service Settings mode The doorstation is displaying a message If no item is selected within several seconds the ME...

Страница 17: ...e 2 Press The LCD is showing 3 Dial the apartment number to which the key will be alloted The LCD is showing the dialed number 4 Press The LCD is showing 5 Apply a blank key to the doorstation key rea...

Страница 18: ...ors selected with the SEL0 or SEL1 terminal can recognize only 2 digit address codes Thus according to the Table of Correspondence programmed in the memory the Control Unit converts apartment numbers...

Страница 19: ...ialling 1 Enter into the Service Settings mode 2 Press The LCD is showing 3 Dial the apartment number the LCD is showing the dialed number 4 Press The LCD is showing 5 Repeat actions 3 to 4 or press t...

Страница 20: ...general access code press then then dial the code Switch shall be ON If the code is valid the door unlocks the doorstation is beeping and the LCD is showing To unlock the entrance door with the indivi...

Страница 21: ...presses the button Press on the doorstation or the Subscriber shall hang up the handset and are ON The LCD is showing The LCD is showing recorded keys then To quit the key memorizing mode press To rec...

Страница 22: ...Lock control parameters across terminals nonregulated voltage load current max switchable current within s in the lock s circuitry Unlocked state duration Max allowable impedance of intercom line Main...

Страница 23: ...Annex Table of correspondence Sequence No Apartment No Sequence No Apartment No 23...

Отзывы: