background image

VZN T5 SERIES

10

P/N 1011066 Rev. G 12/13

CAUTION

Due to its weight and size, the VZN system MUST be 

mounted with the provided Mounting Bracket. Read 

the Mounting the System section before attempting to 

mount the VZN system. Use care when lifting heavy 

objects.

Mounting the System

NOTE: Use caution when lifting and mounting the sys-

tem. The system MUST be mounted using the provided 

Mounting Bracket.

The VZN system comes with a Mounting Bracket. When 

mounting the system, pay attention to the following guidelines:

•  • 

Allow sufficient access for cartridge replacement. 

VZN-421 units should be mounted with 20 inches to the 

left or right. VZN-441 units should be mounted with 40 

inches to the left or right.

•  • 

Mount the system near but NOT above an appropri-

ate electrical outlet.

•  • 

Mount the system near a drain for flushing opera-

tions.

•  • 

Mount the system before all consumable water  

filtration processes.

•  • 

Mount the system with the provided Mounting 

Bracket and hardware capable of supporting 120 lbs. or 

more.

•  • 

Secure the Mounting Bracket into wall studs or with 

the appropriate heavy duty mounting hardware.

The system is pre-assembled to a Back Plate. The Back Plate 

has mounting holes across the bottom portion to secure the 

bottom of the system to the wall. Some of the bottom mount-

INSTALLATION (continued)

ing holes may be obscured. Plan your mounting accordingly.

 

Follow these steps to secure the Mounting Bracket to the wall 

and seat the VZN system:

  1.  Use a stud finder and level to attach the Mounting 

Bracket securely to the wall with the appropriate  

mounting hardware (Figure 2).

  2.  The Mounting Bracket is designed so that the VZN  

system can be lifted and hung on the Mounting Bracket. 

With assistance, lift the system and seat it onto the 

Mounting Bracket securely (Figure 2).

  3.  Secure the bottom portion of the VZN system to the 

wall using the holes provided. Make sure the mounting 

hardware secures the system into wall studs or use the 

appropriate mounting hardware.

  4.  Screw the Carbon Element Housing onto the Carbon 

Element Head without the Carbon Element installed.

NOTE: Do NOT install the Carbon Element at this time. 

The Carbon Element should only be installed after the 

Ultra Filter Cartridge has been rinsed.

  5.  Screw the TAC Housing onto the TAC Head without the 

TAC Cartridge installed.

NOTE: Do NOT install the TAC Cartridge at this time. The 

TAC Cartridge should only be installed after the Ultra 

Filter Cartridge has been rinsed.

Secure Mounting Bracket

to wall studs using

appropriate hardware.

The system is

designed to hang from

the Mounting Bracket.

Back Plate

(holes along bottom 

for additional 

mounting stability)

Figure 2. Mounting the System

Содержание VZN-421H-T5

Страница 1: ...y NSF International and WQA against NSF ANSI Standard 42 and 53 for the reduction of Standard No 42 Aesthetic Effects Nominal Particulate Reduction Class I Standard No 53 Health Effects Cyst Reduction...

Страница 2: ...nt or damage as result of improper use Installation of electrical service Normal maintenance as outlined in this manual Malfunction resulting from improper maintenance Damage from moisture leaking int...

Страница 3: ...olumn and have it handy when calling for assistance The serial number is on the specification plate located on the system OWNER INFORMATION continued IMPORTANT A J Antunes and Company reserves the rig...

Страница 4: ...ll electrical connections must be in accordance with local electrical codes and any other applicable codes WARNING ELECTRICAL SHOCK HAZARD FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS...

Страница 5: ...eaning solutions insecticides Protect from abrasive material The membranes must be protected from abrasive materials like shavings left in a pipe Abrasive materials in contact with the membrane can ca...

Страница 6: ...08 50 60 VZN 441H T5 9700750 100 240 10 08 50 60 Electrical Cord Plug Configurations Kit Model Number Description Configuration 0012146 DC Power Supply 100 240 VAC Includes the 4 plug adaptors below N...

Страница 7: ...ary NOTE The NSF WQA information provided applies to the Ultra Filter cartridge Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or aft...

Страница 8: ...llecting on the membrane wall The Drain Valve is only powered during Flush Mode NOTE Do NOT unplug the power cord or turn off the sys tem during Flush Mode If there is a power outage or the system is...

Страница 9: ...atch the appropriate outlet Do NOT connect the system to a switched electrical outlet PLUMBING NOTE The system must be connected to the COLD water line Do NOT connect the system to the hot water line...

Страница 10: ...the system to the wall Some of the bottom mount INSTALLATION continued ing holes may be obscured Plan your mounting accordingly Follow these steps to secure the Mounting Bracket to the wall and seat...

Страница 11: ...with an appropriate fitting not supplied Figure 3 3 Direct the other end of the hose to the drain Figure 3 When connecting the drain hose pay attention to the follow ing guidelines The drain line plum...

Страница 12: ...gure 6 Do NOT overtighten fittings as this could cause the plastic ball valve to crack Use plastic fittings and a pipe thread sealant approved for use on PVC fittings when making connections Filtered...

Страница 13: ...and wait for five minutes to flush out any remaining air 12 Close the Rinse Ball Valve and disconnect the garden hose 13 Press the FLUSH button to open the Drain Valve Repeat six times to ensure any r...

Страница 14: ...e system until the presence of sanitizer is gone 14 Open all other faucets and taps in line with the system to flush any remaining sanitizer from the plumbing 15 Close all faucets and taps Rinsing the...

Страница 15: ...ght coating of lubricant to the inside cen ter tube at both ends of the new cartridge 10 Record the serial number of the new cartridge The cartridge serial number is engraved on one end of the outer t...

Страница 16: ...ining the Carbon Element into place on the Carbon Element Head The Housing will come to a hard stop at the end of the thread Use a Filter Wrench if necessary NOTE Do NOT overtighten the Carbon Element...

Страница 17: ...The Housing will come to a hard stop at the end of the thread Use a Filter Wrench if necessary 10 Direct water from the Rinse Ball Valve to drain NOTE It is important to direct the Rinse Ball Valve t...

Страница 18: ...will also turn on Figure 12 Universal Pulse Controller Semi Annual Tasks Check Permeate Tank Air Pre Charge It is recommended the permeate tank air charge be checked every six months Tools and suppli...

Страница 19: ...replace the outlet check valve assembly The inlet flow restrictor may be plugged Clean or replace the inlet flow restrictor Water tastes bad Carbon Element need replacing Replace Carbon Element Stora...

Страница 20: ...SERIES 20 P N 1011066 Rev G 12 13 REPLACEMENT PARTS 30 36 37 33 25 25 1 2 39 3 31 12 28 20 14 14 29 16 32 38 14 15 19 4 5 6 7 8 9 11 17 21 13 26 27 18 20 21 22 23 24 24 35 9 8 10 10 34 VZN 421H T5 Sy...

Страница 21: ...ES 21 P N 1011066 Rev G 12 13 30 33 25 1 2 3 31 34 12 20 16 32 14 15 19 4 5 6 7 8 9 11 17 21 13 18 20 21 22 23 24 9 8 10 10 36 37 25 28 14 14 29 26 27 24 35 39 38 REPLACEMENT PARTS continued VZN 441H...

Страница 22: ...34 0505871 VZN Mounting Bracket 1 35 2190154 Adaptor 1 Stem 1 36 2180255 TAC 05 Housing and O Ring 1 37 7000554 TAC 05 Cartridge Kit 1 38 0021667 Flow Regulator Assy 7 9 gpm 1 39 0012146 Power Adapto...

Страница 23: ...VZN T5 SERIES 23 P N 1011066 Rev G 12 13 NOTES...

Страница 24: ...operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or...

Отзывы: