CONFIDENTIAL – DO NOT COPY
Page 2-3
File No. SG-0298
(3) Please attach the surface transparent protective plate to the surface in
order to protect the polarizer. Transparent protective plate should have
sufficient strength in order to the resist external force.
(4) You should adopt radiation structure to satisfy the temperature
specification.
(5) Acetic acid type and chlorine type materials for the cover case are not
desirable because the former generates corrosive gas of attacking the
polarizer at high temperature and the latter causes circuit break by
electro-chemical reaction.
(6) Do not touch, push or rub the exposed polarizers with glass, tweezers or
anything harder than HB pencil lead. And please do not rub with dust
clothes with chemical treatment. Do not touch the surface of polarizer for
bare hand or greasy cloth.(Some cosmetics are detrimental to the
polarizer.)
(7) When the surface becomes dusty, please wipe gently with absorbent
cotton or other soft materials like chamois soaks with petroleum benzine.
Normal-hexane is recommended for cleaning the adhesives used to attach
front / rear polarizers. Do not use acetone, toluene and alcohol because
they cause chemical damage to the polarizer.
(8) Wipe off saliva or water drops as soon as possible. Their long time contact
with polarizer causes deformations and color fading.
(9) Do not open the case because inside circuits do not have sufficient
strength.
9-2. Operating Precautions
(1) The spike noise causes the mis-operation of circuits. It should be lower
than following voltage:
V=±200mV(Over and under shoot voltage)
(2) Response time depends on the temperature.(In lower temperature, it
becomes longer.)
(3) Brightness depends on the temperature. (In lower temperature, it becomes
lower.) And in lower temperature, response time(required time that
brightness is stable after turned on) becomes longer.
(4) Be careful for condensation at sudden temperature change. Condensation
makes damage to polarizer or electrical contacted parts. And after fading
condensation, smearor spot will occur.