Programming the safety threshold of the engine load.
Before switching on the power, connect together 3 wires responsible for the potential-free control (A, B. GND)
Turn on the power.
The motors drive down twice (to the lower end position) and up (to the upper end position). The programming is
completed automatically after the actuators have completed the full two Bottom-Up cycles.
After programming, switch off the power supply and open the wires responsible for the potential-free control (A, B. GND).
Don't stop or touch when programming CP-lift, let it make full movement cycle.
ATTENTION
The emergency shutdown of the engine under load only works when driving up and beyond the angle of 22 degrees (from
the bottom vertical position)
3.
ELECTRIC CONNECTION - CONTROL DIAGRAM:
Manufacturer: VIZ-ART Automation
tel.+48 22/6138899 www.viz-art.eu
5/6
Upper control – Closing adjustment
When turned clockwise - Less
When turned counterclockwise – More
Lower control –Opening adjustment
When turned clockwise - More
When turned counterclockwise - Less