background image

II. Aligning the Finder Scope

IV. Focusing the Finder Scope

It is very difficult for the telescope user to locate a target object through the telescope’s field of view at 

high magnification, especially as the field of view narrows.  The use of a finder scope will make it much 

easier.  Be sure to align the finder scope with the telescope’s field of view before you start observing.

III. Adjusting the Illuminated Reticle

While looking through the finder scope, align the field 

of view with the telescope’s field of view by loosening 

or  tightening  the  adjustment  screws  on  the  finder 

bracket  so  that  the  target  comes  close  to  the  center 

of the field of view. 

Low-profile Finder Bracket

In  the  case  of  the  low-profile  50mm  finder  bracket, 

the top of the tower can be moved toward the center 

of the cross hairs by loosening the adjustment screw 

C and then tightening the adjustment screws A and B.

XY Finder Bracket

In the case of the 50mm XY finder bracket, the top of 

the  tower  can  be  moved  toward  the  center  of  the 

cross hairs by loosening the adjustment screw A and 

then loosening the adjustment screws A.

The  finder  scope  is  adjusted  to  focus  at  infinity  at 

Vixen’s factory before shipment.  Because the ability of 

vision  differs  with  individual  persons,  it  is  possible  that 

you  will  need  to  readjust  the  focus  of  your  7x50  finder 

scope with illuminated reticle.  Following is the procedure.

While looking through the finder scope, turn the rim of 

the finder scope’s eyepiece to left or right by hand to 

bring the crosshairs reticle into focus. 

While holding the lock ring next to the objective lens 

cell of the finder scope, turn the objective lens cell so 

that  it  loosens.    Find  a  position  of  the  objective  lens 

cell that brings a distant view into focus.  Tighten the 

objective lens cell with the lock ring at that position.  

Do not loosen the objective lens cell too much as it 

may detach from the finder scope.

Brightness  of  the  illuminated  reticle  varies  gradually 

as you turn the brightness adjustment dial.   The dial 

will return to the “off” position if you continue turning.  

Stop turning the dial at the brightness appropriate for 

your viewing.

Be sure to turn off the brightness adjustment dial if it 

is  not  in  use.    The  illuminated  reticle  goes  off  when 

the dot mark on the side of the dial is aligned with the 

dot mark on the body. 

Choose a conspicuous target in the 

distance (over 200m away) and place the 

target in the center of a field of view of the 

telescope.   The image in the telescope’s 

field of view is usually upside down.

Next,  look  through  the  finder  scope.   You 

should probably find the same target 

somewhere  within  the  finder’s  field  of 

view.  In the illustration, the tower is seen 

in  the  upper  right  of  the  finder’s  field  of 

view.  The finder scope has cross hairs.

 

Slide the rubber O ring onto the eyepiece 

end  of  the  finder  scope  as  shown  in  the 

figure.

There are two grooves on the finder scope 

tube.  Position the O ring about 6mm short 

of the narrow groove at the middle of the 

finder scope tube.  Straighten the O ring if 

it is twisted.

Loosen the two adjustment screws on the 

finder bracket ring as shown  in  the  figure 

so  that  the  tip  of  the  screws  are 

completely  moved  back  to  allow  passage 

of the finder scope tube.

 Do not touch the fixed stud on the bracket 

   ring as it is a spring-loaded adjuster. 

Slide the finder scope tube into the 

bracket  ring  from  its  eyepiece  end  as 

shown  in  the  figure  4-1  until  the  O  ring 

touches the rim of the bracket ring.

Note1: 

Make sure that the brightness adjustment 

dial is positioned conveniently before you 

slide the finder scope tube into the bracket 

ring.

Note2:  

Take care not to scratch with the tip of the 

adjustment  screws  when  you  slide  the 

finder scope tube into the bracket ring. 

-2

- 1

- 3

Push  the  O  ring  together  with  the  finder 

scope tube into the bracket ring until the O 

ring  fits  snugly.    Confirm  that  the  finder 

scope  tube  is  not  pushed  back  by  the 

rubber O ring.

Tighten  the  two  adjustment  screws 

gradually so that the finder scope tube is 

securely  set  in  the  bracket  ring.    Mount 

the  finder  scope  unit  equipped  with  the 

finder bracket on your telescope. 

- 2

-1

 Dial

 Eyepiece (Rubber rim)

 Lock ring

 Objective lens cell

O ring

Finder scope tube

Adjustment 

screws

O ring

Groove

Finder scope tube

Adjustment 

screws

 Finder 

 bracket 

Adjustment 

screw B

About 

6mm

in width

O ring

Finder scope tube
Finder bracket 

O ring

Power switch

 Finder 

 bracket 

Field of view

O ring

Finder bracket 

Adjustment 

screws

Adjustment 

screw A

Close to the center

Field of view of the finder scope

Field of view of the telescope

XY Finder Bracket

Pushed back

Push

Adjustment 

screw B

Adjustment 

screw C

Field of view

Adjustment 

screw A

Low-profile Finder Bracket

I-(2) Setting up the Finder Scope with 50mm XY Finder Bracket

Отзывы: