VXO8530/3311B 

INSTALLATION GUIDE

 
 

 

PAGE 5 of 5

 

 

 

 

MAINTENANCE 

  Make sure that electrical and fitting connections are regularly inspected, cleaned and tightened when needed. 

  Make sure mounting screws are regularly tightened if needed. 

  Drain weekly, to avoid excessive buildup of condensation. 

  Compressor features a washable air filter which should be cleaned using any mild form of liquid soap every 

two mon

ths if it gets dusty. Just remove the front cover of the filter’s housing to reach it. Replacement time 

frames depend on the operating environment and how often it is used. 

  Clean dirt and dust from heat spreader and motor housing of the compressor. 

 

The motor of the air compressor has a maintenance-free lasting lubricant. 

DO NOT LUBRICATE

.

 

SOLUTIONS TO COMMON ISSUES 

Issue: Compressor inoperable. 

Solution 1: Check all switches to make sure they are ON. 
Solution 2: Check the fuse; if blown, disconnect compressor from power and replace the fuse. 
Solution 3: Allow compressor to cool off for 30-60 minutes. 
Solution 4: Check pressure switch, replace if damaged or inoperable. 

 
Issue: Air horn is inaudible 

Solution 1: Check all switches to make sure they are ON. 
Solution 2: Assure air tank is pressurized. 
Solution 3: Check the fuse; if blown, disconnect compressor from power and replace the fuse.  
Solution 4: Examine electrical connection for damage or corrosion, secure electrical connections. 

 
Issue: Excessive moisture in horn. 

Solution 1: Depressurize and drain the tank. 
Solution 2: Relocate the on-board air system to a drier location. 

 
Issue: Continual cutting-off of Thermal overload protection. 

Solution 1: Relocate the on-board air system to a drier, cooler location. 
Solution 2: Replace the compressor. 

 
Issue: Excessive vibration or noise 

Solution 1: Tighten system components. 
Solution 2: Replace the compressor.  

 
Issue: Loss of pressure of tank when compressor is shut off. 

Solution 1: Tighten drain cock. 
Solution 2: Examine air and check valves and replace if damaged or leaking. 
Solution 3: Use soap and water solution on air connections, and tighten connections or repair leaks where needed. 

 
Issue: Compressor runs continuously and has low air flow. 

Solution 1: Decrease the frequency of use. 
Solution 2: Use soap and water solution on air connections, and tighten connections or repair leaks where needed. 
Solution 3: Clean or replace the air filter element if it is clogged.  
Solution 4: Replace compressor. 

Содержание VXO8530/3311B

Страница 1: ... Hose 6 Feet 30A In line Fuse Horn Button Mounting Hardware SAFETY INSTRUCTIONS Do not attempt to disassemble repair or customize this product Avoid setting up any parts of this product where there is a risk of falling off or risk of coming in contact with water Avoid reaching out to touch or pick up any fallen or water submerged parts Never leave this product unattended during use Intended for us...

Страница 2: ...UR INSTALLATION Before beginning the installation determine each component s spot Confirm you have the proper length of airline and wire Power wire to on board air system should be kept short To power up the on board air system make sure you use a 12 gauge wire or thicker HORN MOUNTING Identify a suitable area for mounting preferably an unobstructed sheet metal surface like the frame or body of th...

Страница 3: ... Thermal Overload Protection if this protection activates cut off the source of power and let the unit cool down for about 30 minutes This will reset the system and allow you to safely resume use of the air compressor PRESSURE SWITCH RATING The included pressure switch has a rating of 95 PSI ON 125 PSI OFF When the air pressure in the air tank is below the preset ON pressure 95 PSI the compressor ...

Страница 4: ... bubble solution to perform this check In case the leak remains after tightening re apply thread sealant IMPORTANT Never touch fittings braided hose or the air compressor with bare hands either during or shortly after use HORN SOLENOID USING NEW HORN BUTTON Connect one of the electric valve s wires to the positive terminal of the battery alternator etc This circuit should be protected using a 10A ...

Страница 5: ...dible Solution 1 Check all switches to make sure they are ON Solution 2 Assure air tank is pressurized Solution 3 Check the fuse if blown disconnect compressor from power and replace the fuse Solution 4 Examine electrical connection for damage or corrosion secure electrical connections Issue Excessive moisture in horn Solution 1 Depressurize and drain the tank Solution 2 Relocate the on board air ...

Отзывы: