background image

 

 

VXO8330APRO/4318B 

INSTALLATION GUIDE

 
 

 

PAGE 2 of 6

 

  It is important to determine the maximum air pressure for any tool or attachment before using it. 

  Air sprayer or nozzle should always be pointed away from any part of the body. 

  The compressor has Thermal Overload Protection, if this protection activates, cut off the source of power and let 

the unit cool down for about 30 minutes. This will reset the system and allow you to safely resume use of the air 
compressor. 

  Make sure your battery ground is detached before you begin. 

  Set the horn up for use only in areas with adequate ventilation. 

  Employ equipment for eye protection during drilling operations. 

  Ensure that your air system has no pressure before you begin. 

 

 

 

 

PLANNING YOUR INSTALLATION 

 

Before beginning the installation, determine each component’s spot. 

  Confirm you have the proper length of airline and wire. 

  Power wire to compressor should be kept short. 

  To power up the air compressor, make sure you use a 12-gauge wire or thicker. 

HORN 

MOUNTING 

  Identify a suitable area for mounting, preferably an unobstructed sheet-metal surface like the frame or body of 

the vehicle so as to provide a firm platform which will help protect the horn from damage due to shaking. 
Never attach the horn to any plastic or other flexible material. 

  Mark the spots for the holes with the bracket and then drill. 

 

The mounting hardware should be used to fasten the horn.

 

 

AIR LINE INSTALLATION

 

  On one side of the included 1/4" OD air line, attach the compression nut and force the air line upon the male 

inlet fitting which is found on the electric solenoid valve. 
 

 

 

  Pass the brass nut through the inlet fitting and fasten. 

 

Take the air line’s other side and place the compression nut of the air tank fitting on it. Force the air line onto 
the male fitting of the tank and then fasten the compression nut. 

WARNING

: Avoid over tightening. 

Содержание VXO8330O/4318B

Страница 1: ...tton Mounting Hardware SAFETY INSTRUCTIONS Do not attempt to disassemble repair or customize this product Avoid setting up any parts of this product where there is a risk of falling off or risk of coming in contact with water Avoid reaching out to touch or pick up any fallen or water submerged parts Never leave this product unattended during use Intended for use by adults only During and immediate...

Страница 2: ...proper length of airline and wire Power wire to compressor should be kept short To power up the air compressor make sure you use a 12 gauge wire or thicker HORN MOUNTING Identify a suitable area for mounting preferably an unobstructed sheet metal surface like the frame or body of the vehicle so as to provide a firm platform which will help protect the horn from damage due to shaking Never attach t...

Страница 3: ...D HOSE INSTALLATION Connect the stainless steel braided hose of the compressor to the tank s inlet port IMPORTANT The tank s inlet port must be 3 8 N P T National Pipe Thread REMOTE AIR FILTER INSTALLATION KIT Only use if you need to move compressor s air intake to an area other than where the compressor was installed A Braided Hose Bracket with Self Anchoring Pin 1 pc B 3 8 NPT Female x 3 8 Barbe...

Страница 4: ...o use as to prevent condensation from entering into the gauge Dropping or disturbing the product can affect the product s accuracy For best results the air gauge should be installed perpendicular to the ground with the zero facing the bottom To tighten the pressure gauge into the air tank place a wrench over the square wrench flats to tum the gauge This is the proper way to avoid air leakage or da...

Страница 5: ...pressor is pumping use soapy water or any bubble solution to perform this check In case the leak remains after tightening re apply thread sealant CAUTION Never touch fittings braided hose or the air compressor with bare hands either during or shortly after use HORN SOLENOID USING NEW HORN BUTTON Connect one of the electric valve s wires to the positive terminal of the battery alternator etc This c...

Страница 6: ... tank is pressurized Solution 3 Check the fuse if blown disconnect compressor from power and replace the fuse Solution 4 Examine electrical connection for damage or corrosion secure electrical connections Issue Excessive moisture in horn or safety valve Solution 1 Depressurize and drain the tank Solution 2 Relocate the compressor to a drier location Issue Continual cutting off of Thermal overload ...

Отзывы: