V3-203 Dispensing System Owner’s Manual
9
Section 3
Technical Specifications
TECHNICAL SPECIFICATIONS
GENERAL DESCRIPTION
The Vivreau V3-203 Dispensing System is designed
to provide Chilled Water on demand.
There are two (2) orientations of the Vivreau V3-203
Dispensing System; Model V3-203A incorporates a
horizontal Chiller and Model V3-203B incorporates
a vertical Chiller.
Performance is the same for both models
and selection is based on space available for
installation.
The system has been designed for operation at
ambient temperatures up to 90ºF.
Dispensing Specifications
Description
Specification
V3-203A
V3-203B
Chilled still water
ΔT=18 °F @ 15.8 gal/h
ü
ü
Water Pressure at Dispensing Head
5 PSI
ü
ü
Operating Conditions
Description
Specification
V3-203A
V3-203B
Temperature
60 – 90°F
ü
ü
Relative Humidity
60% (max.)
ü
ü
Water Supply Requirements
Description
Requirements
V3-203A
V3-203B
1/2” FNPT connection with Ball Valve
1/2”
ü
ü
PSI (min.)
50
ü
ü
GPH (min.)
80
ü
ü
Temperature (max.)
60°F
ü
ü
Drain
Vented Stand-Pipe
ü
ü
Cooler Specifications
Description
V3-203A
V3-203B
Width
25.4”
14.0”
Height
10.0”
27.0”
Depth
15.3”
14.0”
Shipping Weight
76 lbs.
80 lbs.
Voltage
110/120 VAC / 60 Hz
110/120 VAC / 60 Hz
Amperage
11A
11A
Содержание V3-203
Страница 4: ...4 V3 203 Dispensing System Owner s Manual...
Страница 6: ...6 V3 203 Dispensing System Owner s Manual Section 1 Safety Precautions...
Страница 8: ...8 V3 203 Dispensing System Owner s Manual Section 2 General Information...
Страница 10: ...10 V3 203 Dispensing System Owner s Manual Section 3 Technical Specifications...
Страница 14: ...14 V3 203 Dispensing System Owner s Manual Section 4 Pre Installation Requirements...
Страница 18: ...18 V3 203 Dispensing System Owner s Manual Section 5 Operation...
Страница 24: ...24 V3 203 Dispensing System Owner s Manual Section 6 Maintenance...