Vivreau V3-202 Скачать руководство пользователя страница 5

V3-202 Dispensing System Owner’s Manual

  

 5

Section 1

Safety Precautions

SAFETY PRECAUTIONS

 IMPORTANT _________________________

This manual is intended for use only by 
personnel trained in the operation of the 
Vivreau V3-202 Dispensing System.

WARNING

 Improper installation, adjustment, 

alteration, service or maintenance can cause 
property damage, injury, or death. Read the 
installation, operating, and maintenance 
instructions thoroughly before installing or 
servicing this equipment.

WARNING

 Keep the area around the unit 

clear of any combustible materials.

WARNING

 

Do not

 store or use gasoline 

or other flammable vapors or liquids in the 
vicinity of this or any other unit.

 IMPORTANT _________________________

Carefully

 read, understand and follow all 

safety instructions in this manual and safety 
labels on the unit. 

•  Keep safety labels in good condition and 

replace missing or damaged items. 

• 

Learn how to operate the unit and how to use 
the controls properly. 

• 

Do not

 let anyone operate the unit without 

proper training. This unit is intended for use 
by authorized personnel only.

•  In the event of a power failure, 

do not 

attempt to operate this unit.

•  Keep unit in proper working condition and 

do not

 allow unauthorized modifications to 

the unit. 

WARNING

 Only trained and certified electrical, 

plumbing and refrigeration technicians should 
service this unit. 

WARNING

 ALL WIRING AND  PLUMBING 

MUST CONFORM TO NATIONAL AND LOCAL 
CODES. FAILURE TO COMPLY COULD RESULT 
IN SERIOUS INJURY, DEATH OR EQUIPMENT 
DAMAGE. 

SAFETY PRECAUTIONS  ________________

This unit has been specifically designed to 
provide protection against personal injury. 

To ensure continued protection, observe 
the following: 

WARNING

 Disconnect power to the unit 

before servicing. Follow all LOCKOUT/TAGOUT 
procedures. Verify power to the unit is OFF and 
disconnected before any work is performed. Failure 
to do so could result in serious injury, death or 
equipment damage. 

•  To protect against electric shock, do not 

immerse power cord in water or other 
liquid. 

•  To prevent damage to the power cord, do 

not allow cord to hang over the edge of a 
table or counter, or come in contact with 
hot surfaces.

•  Isolate unit from power supply (unplug or 

turn OFF breaker) and turn OFF the water 
supply when not in use and before cleaning. 

•  Allow Boiler (if supplied) to cool before 

removing any components. 

•  The use of spare parts and accessories 

not recommended by Vivreau may cause 
damage and/or injuries. 

• 

Do not

 operate any unit with damaged 

cords, plugs, or after the unit malfunctions 
or has been damaged in any manner. 

• 

Do not

 use outdoors. 

• 

Do not

 place on or near a hot gas or electric 

burner. 

• 

Do not

 use the unit for anything other than 

its intended use. 

• 

Save these instructions.

Содержание V3-202

Страница 1: ...V3 Dispensing System Owner s Manual MODEL V3 202 Freshly drawn Traditionally Served Environmentally Friendly Specially Branded 170205 Model V3 202 ...

Страница 2: ... IMPORTANT_______________ The information contained in this manual is specific to your system It is IMPORTANT you READ FOLLOW and UNDERSTAND the instructions given This manual and all material provided with your system should be retained in a convenient location for future reference Contact Vivreau if you have any questions regarding the information contained in this manual ...

Страница 3: ...pensing System Owner s Manual 3 TABLE OF CONTENTS SAFETY PRECAUTIONS 5 GENERAL INFORMATION 7 TECHNICAL SPECIFICATIONS 9 PRE INSTALLATION REQUIREMENTS 11 OPERATING INSTRUCTIONS 13 MAINTENANCE 17 TROUBLESHOOTING 23 ...

Страница 4: ...4 V3 202 Dispensing System Owner s Manual ...

Страница 5: ...trained and certified electrical plumbing and refrigeration technicians should service this unit WARNING ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY DEATH OR EQUIPMENT DAMAGE SAFETY PRECAUTIONS _________________ This unit has been specifically designed to provide protection against personal injury To ensure continued protection ...

Страница 6: ...6 V3 202 Dispensing System Owner s Manual Section 1 Safety Precautions ...

Страница 7: ... Keep this manual in a clearly identified and safe place throughout the working life of the unit so that it will always be available as needed The manufacturer reserves the right to make modifications to the unit without any obligation to provide prior notice A number of symbols have been used to highlight particularly important parts of the text or important specifications Their meaning is as def...

Страница 8: ...8 V3 202 Dispensing System Owner s Manual Section 2 General Information ...

Страница 9: ... ΔT 18 F 15 8 gal h ü Water Pressure at Dispensing Head 5 PSI ü Operating Conditions Description Specification V3 202 Temperature 60 90 F ü Relative Humidity 60 max ü Water Supply Requirements Description Requirements V3 202 1 2 FNPT connection with Ball Valve 1 2 ü PSI min 50 ü GPH min 80 ü Temperature max 60 F ü Drain ü In lieu of a Stand Pipe Drain the Internal DripTray Container may be used CO...

Страница 10: ...nual Section 3 Technical Specifications Cooler Carbonator Specifications Description Specification V3 202 Width 23 4 ü Height 33 4 ü Depth 23 2 ü Weight Empty 164 lbs ü Weight Operational 201 lbs ü Voltage 110 120 VAC 60 Hz ü Amperage 11A ü ...

Страница 11: ...ICAL OUTLET Model V3 202 1 15 Amp Electrical Receptacle NEMA 5 15R 120V 60 Hz 11 Amps CO2 CO2 Cylinder Customer supplied Size should be selected based on available space A 20 lb cylinder will fit inside unit NOTE If connecting to a bulk or existing CO2 system a CO2 line terminating at a 1 4 Barbed Shutoff Valve must be available within 40 of the unit with 100 PSI minimum pressure DRIPTRAY DRAIN OP...

Страница 12: ...12 V3 202 Dispensing System Owner s Manual Section 4 Pre Installation Requirements ...

Страница 13: ... the unit will beep Please contact Vivreau ServiceToll Free at 877 999 1044 immediately EMPTY DRIPTRAY When the DripTray Container is FULL a Red LED will illuminate and the unit will beep alerting you to empty the Drip Tray Container located just inside the cabinet front door or below the Dispensing System The V3 202 Dispensing System is designed for ease of use IMPORTANT__________________________...

Страница 14: ...en filling is complete IMPORTANT__________________________ Do not allow the Dispenser Handles to slam shut The Dispenser Handles must be closed after each Bottle is filled The Vivreau V3 202 Dispensing System is designed to fill Bottles of up to one 1 liter one Bottle at a time Vivreau Bottles should be filled to the line in the neck just below the Cap IMPORTANT__________________________ Sparkling...

Страница 15: ...lass which may not be visible ALWAYS use Vivreau Storage and Dishwasher Racks DO NOT empty into V3 202 Dispensing System DripTray New Bottles MUST be sanitized before first use ALWAYS inspect Bottles for damage Any Bottles showing signs of damage or cracks should be discarded and recycled appropriately ALWAYS visually check Bottles for food particles or any other solids ALWAYS wash Bottles in a th...

Страница 16: ...sal of tens of billions of plastic bottles Reduces Carbon Footprint by eliminating the unnecessary daily transportation ships trains and trucks of bottled water Water is filtered on demand using advanced micro filtration eliminating 99 99 of bacteria contaminants additives such as chlorine odors and other impurities while allowing the natural minerals to remain for a clean clear taste ...

Страница 17: ...RTANT__________________________ Record all yearly inspections IMPORTANT__________________________ Contact the factory the factory representative or an authorized service agent to perform maintenance and repairs ELECTRICAL LOCKOUT TAGOUT PROCEDURE WARNING Before performing any service that involves electrical connection or disconnection and or exposure to electrical components ALWAYS follow the Ele...

Страница 18: ...ive film Preserve the life of stainless steel with a regular application of a high quality stainless steel polishing cleaner as a final step to daily cleaning If signs of breakdown appear restore the stainless steel surface First thoroughly clean rinse and dry the surface Then on a daily basis apply a high quality stainless steel polish according to manufacturer s instructions HeatTint Darkened ar...

Страница 19: ...ng System is equipped with removable Nozzles for ease of cleaning and sanitizing IMPORTANT__________________________ The Nozzles must be cleaned separately in Sanitizing Solution WARNING Wear protective gloves when handling Sanitizing Solution Fill a small container with Sanitizing Solution Unscrew the Nozzle Dispensing Nozzles Submerge Nozzle and cover in Sanitizing Solution Soak for a minimum of...

Страница 20: ...M CONDENSER GRILLE The Cooling System Condenser Grille is located on the front of the unit CAUTION Condenser Grille must be kept clean to allow proper cooling of components Unit damage will occur due to overheating The Cooling Fins must not be blocked and must maintain a minimum distance of 4 to other objects Never cover the Cooling Fins Never place objects in front of the Cooling Fins Clean the C...

Страница 21: ...inder by quickly opening and closing the Valve on top to clear any dust or moisture from the outlet Connect the High Pressure Hose or Primary Regulator Make sure the Sealing Washer is seated correctly Tighten the Nut firmly using a wrench Open the Valve on top of the Cylinder Check for leaks using a solution of soapy water or a commercial equivalent Checking for Leaks STANDING IDLE Before Long Idl...

Страница 22: ...ct the Water Dispenser from the power supply Disconnect the water supply by closing the Water Supply Valve Clean up the leaked water from the area Indicate the V3 202 Dispensing System is out of service by hanging a DO NOT USE sign on the Dispensing Head Contact Vivreau ServiceToll Free at 877 999 1044 CO2 Disconnect the Water Dispenser from the power supply Close the CO2 Cylinder Valve Open the w...

Страница 23: ... NO SPARKLING WATER If only gas is coming out check the main Water Supply or power If nothing is coming out check CO2 Cylinder and change if needed LED DISPLAY LED Panel Dispensing Head System LED Display Panel POWER Make sure unit is plugged in CHANGE CO2 Replace CO2 Cylinder CALL SERVICE Unplug unit and check still water If still water is not working check Water Block and water supply Plug in un...

Страница 24: ...24 V3 202 Dispensing System Owner s Manual Section 7 Troubleshooting NOTES ...

Страница 25: ...V3 202 Dispensing System Owner s Manual 25 Section 7 Troubleshooting NOTES ...

Страница 26: ...26 V3 202 Dispensing System Owner s Manual Section 7 Troubleshooting NOTES ...

Страница 27: ...V3 202 Dispensing System Owner s Manual 27 ...

Страница 28: ...New Zealand Tel 64 9 377 8621 VIVREAU Ireland 44 0 845 674 9655 email info vivreau ie VIVREAU USA 1 877 999 1044 email infousa vivreau com VIVREAU South Africa 27 21 671 6306 email info vivreau co za Tel 64 9 377 8621 VIVREAU Switzerland 41 0 22 344 86 70 email info vivreau ch VIVREAU Canada 1 877 999 1044 email infocanada vivreau com VIVREAU Australia Tel 61 3 9590 0886 VIVREAU Poland Email info ...

Отзывы: