10
|
EN
EN |
11
sure relief valve.
Water pressure regulator
According to ASSE1022 the
water dispenser is installed with
a water pressure regulator and a
controllable backflow preventer.
The water pressure regulator
reduces the inlet water pressure.
The water pressure regulator
is preset to 4 bar / 58 psi. This
pressure must not be changed
without authorization.
Affixed labels and notices
Danger of illegible labelling!
Over time, stickers and signs my
become dirty or indecipherable
for other reasons, meaning that
dangers are not recognized and
necessary operating instructions
cannot be followed. There is dan-
ger of injury as a result.
•
Always keep all safety, warning
and operating instructions
clearly legible.
•
Replace damaged signs or
stickers immediately.
Spare parts
The use of incorrect spare parts
can cause damage and malfunc-
tion of the water dispenser.
•
Only use original spare parts
from VIVREAU or spare parts
approved by VIVREAU. The
device must be connected to
the water supply using new
pipes only. Old hoses must
never be reused.
•
Never attempt the unauthorized
repair of the water dispenser.
•
Servicing shall be done by
factory authorized service
personnel, so as to minimize
the risk of possible ignition due
to incorrect parts or improper
service. For repair work, con-
tact customer services (see
rear page).
A list of the original spare parts
is available from the manufactur-
er, customer services or special
retailer.
Endangerment of the environ-
ment from improper handling
of environmentally hazardous
substances!
The improper handling of en-
vironmentally hazardous sub-
stances, particularly improper
disposal, can lead to substantial
damage to the environment.
•
Always follow the notes stat-
ed below for the handling of
environmentally hazardous
substances and their disposal
in compliance with all laws and
regulations.
SAFETY INSTRUCTIONS
Safety equipment
Danger through malfunction-
ing safety equipment!
If safety equipment is not func-
tioning or is inoperative, there is
a danger of very severe injury or
death.
•
Before starting up, check that
all safety equipment is in good
working order and correctly
installed.
•
Never make safety equipment
inoperative or bypass it.
•
Ensure that all safety equip-
ment is accessible at all times.
The safety equipment installed in
the device is listed below.
Aquastop
The aquastop is located between
the water shut-off valve and
the water supply of the water
dispenser.
A sensor inside detects the
quantity of water passing
through. When the registered
amount exceeds 2.6 gallons of
continuous flow, the aquastop
valve automatically shuts off the
water supply.
1
2
CO
2
pressure regulator and
pressure relief valve
The CO
2
pressure regulator
is mounted on the CO
2
bottle.
The mounted gauge indicates
the applied CO
2
pressure in PSI.
The left gauge
1
indicates the
CO
2
pressure and the filling level
of the CO
2
bottle.
The right gauge
2
indicates the
CO
2
pressure applied to the ap-
pliance. The optimum setting is
4.5 bar/ 65 psi.
For additional safety, the CO
2
pressure regulator has a pres-
Содержание Top 85