![Vivotek VS8100 Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/vivotek/vs8100/vs8100_user-manual_1040996135.webp)
VIVOTEK
User's Manual - 135
separated by “,”
patroldwelling
string[160]
<blank>
1/4
(For external device)
The dwelling time of each patrol
point, separated by “,”
7.18 UART control
Group:
uart
(capability.nuart > 0)
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40]
<blank>
1/4
Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128]
<blank>
1/4
Full path of the PTZ driver.
enablehttptunnel
<boolean>
0
1/4
Enable HTTP tunnel channel to
control UART.
Group:
uart_i<0~(n-1)>
n is uart port count
(capability.nuart > 0)
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600,120
0,2400,3600,480
0,7200,9600,192
00,38400,57600,
115200
9600
4/4
Set baud rate of COM port.
databit 5,6,7,8
8
4/4
Data bits in a character frame.
paritybit none,
odd,
even
none
4/4
For error checking.
stopbit
1,2 1 4/4 1
2-1.5 , data bit is 5
2-2
uartmode
rs485
rs485
4/4
UART transmission mode.
customdrvcmd_i<0~9
>
string[128]
<blank>
1/4
PTZ command for custom
camera.
speedlink_i<0~4>_na
me
string[40]
<blank>
1/4
Additional PTZ command
name.
speedlink_i<0~4>_c
string[40]
<blank>
1/4