VIVOTEK
192 - User's Manual
profile_i<0~(m-1)>_saturation
percent
0~100
4/4
Set saturation in the normalized range.
0: Less saturation <-> 100: More saturation
* Only available when bit 2 of
"capability_image_c<n>_basicsetting" is 1.
profile_i<0~(m-1)>_sharpness
percent
0~100
4/4
Set sharpness in the normalized range.
0: Softer <-> 100: Sharper
* Only available when bit 3 of
"capability_image_c<n>_basicsetting" is 1
profile_i<0~(m-1)>_gammacur
ve
0~100
4/4
0: Fine-turned gamma curve by Vivotek.
1: Gamma value = 0.01
2: Gamma value = 0.02
3: Gamma value = 0.03
...
100: Gamma value = 1
* Note: Although we set gamma value to 100
level, but not all gamma values are valid.
Internal module will take the closest valid one.
For example, 1~45 may all be mapped to
gamma value = 0.45, etc.
profile_i<0~(m-1)>_lowlightm
ode
<product dependent>
<boolean>
4/4
Enable/disable low light mode.
* Only available when
"capability_image_c<n>_lowlightmode" is 1
profile_i<0~(m-1)>_dnr_mode
<product dependent>
<boolean>
4/4
3D noise reduction.
0:disable
1:enable
* Only available when
"capability_image_c<n>_dnr" is 1
profile_i<0~(m-1)>_dnr_stren
gth
<product dependent>
1~100
4/4
Strength of 3DNR
* Only available when
"capability_image_c<n>_dnr" is 1
profile_i<0~(m-1)>_defog_mo
de
<product dependent>
<boolean>
4/4
Enable/disable defog mode.
0:disable
1:enable
* Only available when
"capability_image_c<n>_defog_mode" is 1
profile_i<0~(m-1)>_defog_str
ength
1~100
4/4
Strength of defog
* Only available when