![Vivotek SD8111 Скачать руководство пользователя страница 129](http://html1.mh-extra.com/html/vivotek/sd8111/sd8111_user-manual_1040899129.webp)
VIVOTEK
User's Manual - 129
Group:
event_i
<0~2>
PARAMETER
VALUE
SECURITY
(get/set)
DESCRIPTION
name
string[40]
6/6
Identification of this entry.
enable
0, 1
6/6
Enable or disable this event.
priority
0, 1, 2
6/6
Indicate the priority of this event:
“0” = low priority
“1” = normal priority
“2” = high priority
delay
1~999
6/6
Delay in seconds before detecting the next event.
trigger boot,
di,
motion,
seq,
recnotify,
6/6
Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“recnotify” = Recording notification.
triggerstatus
String[40]
6/6
The status for event trigger
di
<integer>
6/6
Indicate which DI detects.
This field is required when trigger condition is “di”.
One bit represents one digital input. The LSB
indicates DI 0.
mdwin
<integer>
6/6
Indicate which motion detection windows detect.
This field is required when trigger condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set
mdwin as 5.
mdwin0
<integer>
6/6
Similar to mdwin. The parameter takes effect when
profile 1 of motion detection is enabled.
inter
1~999
6/6
Interval of snapshots in minutes.
This field is used when trigger condition is “seq”.
Содержание SD8111