8.37 Optimized IR control
(capability_daynight_c<0~(n-1)>_optimizedir > 0)
Note:
This request requires Administrator privileges.
Method:
GET/POST
Syntax:
http://<
servername
>/cgi-bin/admin/optimizedir.cgi?function=<value>[&channel=<value
>]
PARAMETER VALUE
DESCRIPTION
channel
0~"capability_nvideoin"-1 Channel of the video source.
function
getstatus,
onetimeauto
"onetimeauto"
: Camera will automatically adjust the IR
zone one time only.
"getstatus"
: Information of optimized IR control status and
return value as below:
optimizedir_c<0~(n-1)>_irmode:
Indicate the IR current mode, available value is “auto” and
“manual” mode.
optimizedir_c<0~(n-1)>_irnum:
The number of IR that camera supports.
optimizedir_c<0~(n-1)>_irstrength:
Only available when irmode is set as manual. It’s a set of
integers, which indicate the strength of each IR LED (e.g.
23,45,100,100).
optimizedir_c<0~(n-1)>_irstatus:
Current IR status, normal / adjusting:
"normal":
the IR LED strength has been fixed.
"adjusting":
the IR LED strength is adjusting.
Example:
Содержание MS9321-EHV