PTZ
Mechanical PTZ Configuration
Select the “Mechanical” tab to display the RS485 Settings:
RS485 Settings
Disable
: Select this option to disable this function.
PTZ camera
: Select this option to enable PTZ operation.
To utilize this feature, please connect the Network Camera to a PTZ driver or scanner via RS485 serial
interface first. Then you can configure the PTZ driver and RS485 port with the following settings.
VIVOTEK provides the following PTZ drivers: DynaDome/SmartDOME, Lilin PIH-7x00, Pelco D, and
Pelco P protocol. If none of the above PTZ drivers is supported by your PTZ scanner, please select
Custom camera
(scanner). Please refer to the documentation of your PTZ scanner to determine the
Camera ID, PTZ driver, and Port settings. The Camera ID is necessary to control multiple cameras. If
you click
Save
to enable this function, the camera control panel will be displayed on the main page.
There is a terminator circuit on the RS485 bus, and can not be turned off.