50
trigger boot,
di,
motion,
seq,
recnotify,
tampering,
vi,
boot
6/6
Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
triggerstatus
string[40]
trigger
6/6
The status for event trigger
di
0~3
1
6/6
Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
vi
0~7
0
6/6
Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input.
The LSB indicates VI 0.
mdwin
0~7
0
6/6
Indicate the source window id of
motion detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0
0~7
0
6/6
Similar to mdwin. The parameter
takes effect when profile 1 of motion
detection is enabled.
inter
1~999
1
6/6
Interval of snapshots in minutes.
This field is used when trigger