VIVOTEK
154 - User's Manual
action_patrol_enable
(only for VS series)
<product dependent>
<Boolean> 6/6
Enable/disable ptz patrol when event triggered. (not used in
IP8362)
action_ patrol _server
(only for VS series)
<product dependent>
0~255
6/6
Indicate the target servers to which the snapshots taken
during patrol dwelling time should be sent.
One bit represents one application server (server_i0~i4).
bit0 (LSB) = server_i0.
bit1 = server_i1.
bit2 = server_i2.
bit3 = server_i3.
bit4 = server_i4.
For example, enable server_i0, server_i2, and server_i4 as
notification servers; the notifyserver value is 21.
(not used in IP8362)
7.31 Server setting for event action
Group:
server_i
<0~4>
PARAMETER
VALUE
SECURITY
(get/set)
DESCRIPTION
name
string[40]
6/6
Identification of this entry
type email,
ftp,
http,
ns
6/6
Indicate the server type:
“email” = email server
“ftp” = FTP server
“http” = HTTP server
“ns” = network storage
http_url
string[128]
6/6
URL of the HTTP server to upload.
http_username
string[64]
6/6
Username to log in to the server.
http_passwd
string[64]
6/6
Password of the user.
ftp_address
string[128]
6/6
FTP server address.
ftp_username
string[64]
6/6
Username to log in to the server.
ftp_passwd
string[64]
6/6
Password of the user.
ftp_port
0~65535
6/6
Port to connect to the server.
ftp_location
string[128]
6/6
Location to upload or store the media.
ftp_passive
0, 1
6/6
Enable or disable passive mode.
0 = disable passive mode
1 = enable passive mode
email_address
string[128]
6/6
Email server address.
email_sslmode
0, 1
6/6
Enable support SSL.