![Vivotek IP7161 Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/vivotek/ip7161/ip7161_user-manual_1040697070.webp)
VIVOTEK
70 - User's Manual
Transparent HTTP Tunnel: If you want to use your own RS-485 device, you can use UART commands to
build a Transparent HTTP Tunnel� The UART commands will be sent through HTTP tunnel established
between the RS-485 device and the linked camera� For detailed application notes, please refer to URL
Commands on page 105 or
http://www.vivotek.com/downloadfiles/faq/videoserver/UART_HTTP_Tunnel.
pdf�
Preset Positions
If you select DynaDome/SmartDOME, Lilin PIH-7x00, or Pelco D protocol as the PTZ driver and click
the
Save
button, the
Preset Position
button will be enabled� Click
Preset Position
to open the settings
page� You can also select preset positions for the camera to patrol� A total of 20 preset positions can be
configured.
Please follow the steps below to preset a position:
1� Adjust the shooting area to the desired position using the buttons on the right side of the window�
2� Enter a name for the preset position, which allows for up to forty characters� Click
Add
to enable the
settings� The preset positions will be displayed under the Preset Location list on the left-hand side�
3� To add additional preset positions, please repeat steps 1~2�
4� To remove a preset position from the list, select it from the drop-down list and click
Delete
�
5� The preset positions will also displayed on the main page� Please refer to the illustration on the next
page�
6� Click
Save
to enable the settings�
Functions are the same
as the Control Panel on
the home page
1