Where state is 0 or 1; “0” means inactive or normal state, while “1” means active or triggered state.
PARAMETER
VALUE
DESCRIPTION
0 – Inactive, normal state
do<num>
0, 1
1 – Active, triggered state
return
<return page>
Redirect to the page
<return page>
after the parameter is
assigned
.
The
<return page>
can be a full URL path or relative
path according to the current path. If you omit this parameter, it
will redirect to an empty page.
Example:
Drive the digital output 1 to triggered state and redirect to an empty page.
http://myserver/cgi-bin/dido/setdo.cgi?do1=
1
Query Status of the Digital Input
Note:
This request requires Viewer privileges.
Method:
GET/POST
Syntax:
http://<
servername
>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]
If no parameter is specified, all of the digital input statuses will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length:
<length>
\r\n
\r\n
[di0=<state>]\r\n
[di1=<state>]\r\n
[di2=<state>]\r\n
[di3=<state>]\r\n
where
<state>
can be 0 or 1.
Example:
Query the status of digital input 1
Содержание IP7153