- 69 -
www.vivotek.com
T:
886-2-82455282
F:
886-2-82455532
[&<parameter>=<value>…][&update=<value>] [&return=<return page>]
http://<servername>/cgi-bin/
operator
/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>…][&update=<value>] [&return=<return page>]
http://<servername>/cgi-bin/
admin
/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>…][&update=<value>] [&return=<return page>]
PARAMETER
VALUE
DESCRIPTION
<group>_<name>
value to assigned Assign <value> to the parameter <group>_<name>
update
<boolean>
set to 1 to actually update all fields (no need to use
update parameter in each group)
return
<return page>
Redirect to the page <return page> after the
parameter is assigned. The <return page> can be a
full URL path or relative path according the the current
path. If you omit this parameter, it will redirect to an
empty page.
(note: The return page can be a general HTML
file(.htm, .html) or a Vivotek server script executable
(.vspx) file. It can not be a CGI command. It can not
have any extra parameters. This parameter must be
put at end of parameter list)
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: <length>\r\n
\r\n
<parameter pair>
where <parameter pair> is
<parameter>=<value>\r\n
[<parameter pair>]