VIVOTEK
188 - User's Manual
* We support this parameter when the
version number (httpversion) is equal
or greater than 0302a.
* Only available when
"capability_image_c<0~(n-1)>_expo
sure_mode" !=0
irismode
fixed, indoor, outdoor
<product dependent>
4/4
Control DC-Iris mode.
"outdoor"
: Auto-setting DC-Iris to
get best quality, but easy to meet
rolling or flicker effect in indoor
environment.
"indoor"
: Avoid rolling and flicker
effect first.
"fixed"
: Open the iris to maximum.
* Only available when
"capability_image_c<0~(n-1)>_iristy
pe"=dciris
piris_mode
<product
dependent>
manual, indoor, outdoor,-
1/4
Control P-Iris mode.
"outdoor"
: Auto-setting P-Iris to get
best quality, but easy to meet rolling or
flicker effect in indoor environment.
"indoor"
: Avoid rolling and flicker
effect first.
"manual"
: Manual set P-Iris by
"piris_position".
"-"
: not support. (only available when
"capability_image_c<0~(n-1)>_sens
ortype" is "smartsensor")
* Only available when
"capability_image_c<0~(n-1)>_iristy
pe"=piris
piris_position
<product
dependent>
1~100
1/4
Manual set P-Iris.
1: Open <-> 100: Close
* Only valid when
"piris_mode"=manual or
"capability_image_c<0~(n-1)>_sens
ortype" is "smartsensor"
* Only available when