VIVOTEK
User's Manual - 177
URL Command Document for All Series
7.31 Exposure window setting per channel
Group:
exposurewin_c<0~(n-1)>
for n channel products
NAME
VALUE
DEFAULT SECURITY
(get/set)
DESCRIPTION
mode
auto, custom, blc auto
4/4
The mode indicates how to
decide the exposure.
auto: Use full view as the only
one exposure window.
custom: Use inclusive and
exclusive window.
blc: Use BLC.
win_i0_enable <boolean>
1
4/4
Enable or disable the window.
win_i0_policy 0~1
1
4/4
0: Indicate exclusive.
1: Indicate inclusive.
win_i0_home <coordinate>
80,60
4/4
Left-top corner coordinate of the
window.
<x,y> => <”0~288”, “0~208”>
win_i0_size
<window size>
160x120
4/4
Width and height of the window.
<wxh> =>
<”0~320”x”0~240”>
Group:
exposurewin_c<0~(n-1)>_profile
for m profile and n channel product
NAME
VALUE
DEFAULT SECURITY
(get/set)
DESCRIPTION
i0_mode
auto, custom, blc auto
4/4
The mode indicates
how to decide the
exposure.
auto: Use full view
as the only one
exposure window.
custom: Use
inclusive and
exclusive window.
blc: Use BLC.
i0_win_i0_enable
<boolean>
1
4/4
Enable or disable the
window.