VIVOTEK
126 - User's Manual
1 => Active
(capability.nvi > 0)
7.3 digital input behavior define
Group:
di_i<0~(ndi-1)>
(capability.ndi > 0)
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
high
1/1
Indicates open circuit or
closed circuit (inactive
status)
7.4 digital output behavior define
Group:
do_i<0~(ndo-1)>
(capability.ndo > 0)
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
normalstate open,
grounded
open
1/1
Indicate open circuit or
closed circuit (inactive
status)
7.5 security
Group: security
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
privilege_do
view, operator,
admin
operator
6/6
Indicate which privileges
and above can control
digital output
(capability.ndo > 0)
privilege_camctrl
view, operator,
admin
view
6/6
Indicate which privileges
and above can control PTZ
(capability.ptzenabled > 0
or capability.eptz > 0)
user_i0_name
string[64]
root
6/7
User name of root
user_i<1~20>_name
string[64]
<blank>
6/7
User name
user_i0_pass
password[64]
<blank>
6/6
Root password
user_i<1~20>_pass
password[64]
<blank>
7/6
User password
user_i0_privilege viewer,
operator,
admin
6/7
Root privilege