Group: event_customtaskfile_i<0~2>
PARAMETER
VALUE
SECURITY
(get/set)
DESCRIPTION
name
string[40]
6/6
Custom script identification of this entry.
date
string[17]
6/6
Date of custom script.
time
string[17]
6/6
Time of custom script.
Group: event_i<0~2>
PARAMETER
VALUE
SECURITY
(get/set)
DESCRIPTION
name
string[40]
6/6
Identification of this entry.
enable
0, 1
6/6
Enable or disable this event.
priority
0, 1, 2
6/6
Indicate the priority of this event:
“0” = low priority
“1” = normal priority
“2” = high priority
delay
1~999
6/6
Delay in seconds before detecting the next event.
trigger
boot,
di,
motion,
seq,
visignal,
pir,
recnotify,
audioswitch,
tampering
6/6
Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“visignal” = Video input signal loss.
“pir” = PIR detection.
“recnotify” = Recording notification.
“audioswitch” = Audio switch.
“tampering” = Tamper detection.
mdwin
<integer>
6/6
Indicate which motion detection windows detect.
This field is required when trigger condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set
mdwin as 5.
inter
1~999
6/6
Interval of snapshots in minutes.
This field is used when trigger condition is “seq”.