VIVOTEK
176 - User's Manual
...
100: Gamma value = 1
* Note: Although we set gamma value to 100
level, but not all gamma values are valid.
Internal module will take the closest valid one.
For example, 1~45 may all be mapped to
gamma value = 0.45, etc.
profile_i0_lowlightmode
<product dependent>
<boolean>
4/4
Enable/disable low light mode.
* Only available when
"capability_image_c<n>_lowlightmode" is 1
profile_i0_dnr_mode
<product dependent>
<boolean>
4/4
3D noise reduction.
0:disable
1:enable
* Only available when
"capability_image_c<n>_dnr" is 1
profile_i0_dnr_strength
<product dependent>
1~100
4/4
Strength of 3DNR
* Only available when
"capability_image_c<n>_dnr" is 1
profile_i0_defog_mode
<product dependent>
<boolean>
4/4
Enable/disable defog mode.
0:disable
1:enable
* Only available when
"capability_image_c<n>_defog_mode" is 1
profile_i0_defog_strength
<product dependent>
1~100
4/4
Strength of defog
* Only available when
"capability_image_c<n>_defog_mode" is 1
profile_i0_eis
<product dependent>
<boolean>
4/4
Electronic image stabilizer
0:disable
1:enable
* Only available when
"capability_image_c<n>_eis" is 1
profile_i0_scene_enable
<product dependent>
<boolean>
4/4
Enable/disable scene mode
0: disable
1: enable
* Only available when
"capability_image_c<n>_scenemode_support
" is 1
profile_i0_scene_mode
<product dependent>
visibility,
noiseless,
4/4
Value of scene mode
* Only available when