Vivotek 4712123676418 Скачать руководство пользователя страница 2

2

Revision History:

* Rev. 1.0: Initial Release     

* Rev. 1.1: Updated illumination range and beam angles. Added the 

rear panel plug opener.  

* Rev. 1.2: Added safety instructions and warning messages. 

Package Contents

X3

X1

X2

X2

• 

The wall-mount (CMA-B04), corner-mount (AM-412), pole-

mount adaptor (AM-311/312), and other brackets are separately 

purchased.

• 

The screws and anchors for securing the illuminator to wall are 

user-supplied. Apply M6 anchors or screws.    

NOTE:  

• 

Please avoid eye exposure or apply appropriate protection, such as wearing a pair of Infrared 

protection glasses, when working with the product. Always use camera live view to oberve IR 

lighting effects. 

WARNING:  

The 1/4" screws and washers are used to secure the illuminator 

to an external camera housing. 

• 

The luminaire should be positioned so that prolonged staring into the luminaire at a distance 

closer than 2.5 m is not expected.

• 

The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, 

the luminaire shall be destroyed.

• 

The light source of this luminaire is not replaceable; when the light source reaches its end of life 

the whole luminaire shall be replaced.

• 

Please make sure Reinforce/Double insulation shall be maintained between LV supply and control 

circuits after installation.

• 

This flood light shall be used with a IEC/EN 61347-2-13 approved LED driver with SELV output 

equal to rated voltage of the luminaire, and output power of LED drivers shall be at least equal to 

rated power of the luminaire.

• 

Terminal block is not included. Installation may require advice from a qualified personnel.      

Содержание 4712123676418

Страница 1: ...Installation Guide CM48 Series Vari Angle IR Illuminator Rev 1 2 QIG Part no 625037102G...

Страница 2: ...o secure the illuminator to an external camera housing The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 2 5 m is not expected The external flex...

Страница 3: ...RTANT Class III luminaires Do not stare at the operating light source This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible...

Страница 4: ...4 160mm 6 3 220mm 8 7 73mm 2 9 103 8mm 4 1 134 6mm 5 3 61 5mm 2 4 164 6mm 6 5 59 5mm 2 3 43mm 1 7 43mm 1 7 59mm 2 3 32mm 1 3 Mechanical Drawings 134 M6x1 4 64 29 3 8 2 30 82 Standard Small U bracket...

Страница 5: ...r external camera housing U bracket Waterproof cover for angle selector Optional mounting points for U bracket Light sensor Combo cable Dehumidifier membrane Reserved Mounting holes Unit Weight 2 1KG...

Страница 6: ...ientation Use the included allen wrench to attach and adjust the U bracket to your needs at the installation site It is highly recommended that the illuminator should be installed at a position higher...

Страница 7: ...e of the allen wrench to turn the beam angle to an estimated illumination distance e g 200 meters See the tables on the next page for how to do it You may forget your current beam angle configuration...

Страница 8: ...9 150 77 6 212 1 109 7 259 8 134 4 3 27 158 75 9 223 4 107 3 273 7 131 4 4 20 200 70 5 282 8 99 7 346 4 122 2 Counter clockwide Narrower Clockwide Wider The factory default for the beam angle selector...

Страница 9: ...tance m Width m Distance m Width m 0 120 45 155 9 63 6 220 5 77 9 270 0 1 105 50 130 3 70 7 184 3 86 6 225 7 2 90 55 110 0 77 8 155 6 95 3 190 5 Counter clockwide Narrower Clockwide Wider Counter cloc...

Страница 10: ...4 57 9 54 3 81 8 66 5 100 2 3 66 40 2 52 2 56 9 73 8 69 6 90 4 4 63 41 4 50 7 58 5 71 8 71 7 87 9 5 60 42 6 49 2 60 2 69 6 73 8 85 2 6 55 45 46 9 63 6 66 3 77 9 81 1 7 52 47 4 46 2 67 0 65 4 82 1 80 1...

Страница 11: ...11 Select a position at the installation site e g under a hanging roof You can use the alignment sticker and start drilling a hole on the roof Apply the included grip sticker to the U bracket...

Страница 12: ...hor Hammer the anchor in user supplied M6 anchors are recommended Secure the U bracket to it such as securing it using the bolt on a threaded pole Secure the illuminator to bracket using the hex socke...

Страница 13: ...illuminator to precisely match the illuminated area with the camera s field of view If necessary adjust the beam angle again Turn the illuminator toward the FOV of the partner camera shift the tilt an...

Страница 14: ...ntrol Dry contact Logic level 1 Open LED off Logic level 0 Close to GND LED on Wet contact Logic level 1 4V 40 V LED off Logic level 0 0 8V MAX LED on DI Yellow 26AWG Ground DO Purple 26AWG Light sens...

Страница 15: ...Green Yellow wires This mode means that CaMate illuminator On Off control is triggered by camera or other alarm system User can decide using the appropriate dry wet contacts depending on wiring condit...

Страница 16: ...ent must be under 100mA DO Bule GND Light sensor status output 1 Open Day 2 Short Night lower than 300 lux for IR to turn ON Stand alone illuminator mode This mode means that the illuminator s On Off...

Отзывы: