background image

Installation Guide

CM48 Series

Vari-Angle IR Illuminator

Rev. 1.2

QIG Part no.: 625037102G

Содержание 4712123676418

Страница 1: ...Installation Guide CM48 Series Vari Angle IR Illuminator Rev 1 2 QIG Part no 625037102G...

Страница 2: ...o secure the illuminator to an external camera housing The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 2 5 m is not expected The external flex...

Страница 3: ...RTANT Class III luminaires Do not stare at the operating light source This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible...

Страница 4: ...4 160mm 6 3 220mm 8 7 73mm 2 9 103 8mm 4 1 134 6mm 5 3 61 5mm 2 4 164 6mm 6 5 59 5mm 2 3 43mm 1 7 43mm 1 7 59mm 2 3 32mm 1 3 Mechanical Drawings 134 M6x1 4 64 29 3 8 2 30 82 Standard Small U bracket...

Страница 5: ...r external camera housing U bracket Waterproof cover for angle selector Optional mounting points for U bracket Light sensor Combo cable Dehumidifier membrane Reserved Mounting holes Unit Weight 2 1KG...

Страница 6: ...ientation Use the included allen wrench to attach and adjust the U bracket to your needs at the installation site It is highly recommended that the illuminator should be installed at a position higher...

Страница 7: ...e of the allen wrench to turn the beam angle to an estimated illumination distance e g 200 meters See the tables on the next page for how to do it You may forget your current beam angle configuration...

Страница 8: ...9 150 77 6 212 1 109 7 259 8 134 4 3 27 158 75 9 223 4 107 3 273 7 131 4 4 20 200 70 5 282 8 99 7 346 4 122 2 Counter clockwide Narrower Clockwide Wider The factory default for the beam angle selector...

Страница 9: ...tance m Width m Distance m Width m 0 120 45 155 9 63 6 220 5 77 9 270 0 1 105 50 130 3 70 7 184 3 86 6 225 7 2 90 55 110 0 77 8 155 6 95 3 190 5 Counter clockwide Narrower Clockwide Wider Counter cloc...

Страница 10: ...4 57 9 54 3 81 8 66 5 100 2 3 66 40 2 52 2 56 9 73 8 69 6 90 4 4 63 41 4 50 7 58 5 71 8 71 7 87 9 5 60 42 6 49 2 60 2 69 6 73 8 85 2 6 55 45 46 9 63 6 66 3 77 9 81 1 7 52 47 4 46 2 67 0 65 4 82 1 80 1...

Страница 11: ...11 Select a position at the installation site e g under a hanging roof You can use the alignment sticker and start drilling a hole on the roof Apply the included grip sticker to the U bracket...

Страница 12: ...hor Hammer the anchor in user supplied M6 anchors are recommended Secure the U bracket to it such as securing it using the bolt on a threaded pole Secure the illuminator to bracket using the hex socke...

Страница 13: ...illuminator to precisely match the illuminated area with the camera s field of view If necessary adjust the beam angle again Turn the illuminator toward the FOV of the partner camera shift the tilt an...

Страница 14: ...ntrol Dry contact Logic level 1 Open LED off Logic level 0 Close to GND LED on Wet contact Logic level 1 4V 40 V LED off Logic level 0 0 8V MAX LED on DI Yellow 26AWG Ground DO Purple 26AWG Light sens...

Страница 15: ...Green Yellow wires This mode means that CaMate illuminator On Off control is triggered by camera or other alarm system User can decide using the appropriate dry wet contacts depending on wiring condit...

Страница 16: ...ent must be under 100mA DO Bule GND Light sensor status output 1 Open Day 2 Short Night lower than 300 lux for IR to turn ON Stand alone illuminator mode This mode means that the illuminator s On Off...

Отзывы: