4K HDBT Splitter 1x4 with PoC
Please set the parameters of COM number, bound rate, data bit, stop bit and the parity
bit correctly, only then will you be able to send command in Command Sending Area.
Note:
To control VL120013 via RS232 port, the communication protocol parameters
should be configured in the right manner: Baud rate: 9600; Data bit: 8; Stop bit: 1; Parity
bit: none.
4.2.3 RS232 Communication Commands
Command
Function
Feedback Example
EDIDUpgrade[x][y].
Upgrade EDID data via serial port;
[X]
: unit ID, varies from 00~15;
[Y]
: serial number of embedded
EDID, varies from 0~4 (correspond
to embedded EDID 1~5 separately).
Connect input source and keep
energized
before
sending
this
command.
WAIT FOR EDID
FILE
[X][Y] [Q1],[Q2]$[Z]
Send command to several HDBT
Parameter Configuration area
Monitoring area, indicates
whether the command
sent works.
Command Sending area
Parameter Configuration area
Monitoring area, indicates
whether the command
sent works.
Command Sending area
14