Compact Scaler Switcher 6x1
Please set the parameters of COM number, bound rate, data bit, stop bit and the parity
bit correctly, only then will you be able to send command in Command Sending Area.
4.2.3 RS232 Communication Commands
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
Command
Function
Feedback Example
Switch Commands
50701%
Switch to HDMI 1 Input
Switch to HDMI 1
50702%
Switch to HDMI 2 Input
Switch to HDMI 2
50703%
Switch to HDMI 3 Input
Switch to HDMI 3
50704%
Switch to HDMI 4 Input
Switch to HDMI 4
50705%
Switch to VGA 1 input
Switch to VGA 1
50706%
Switch to VGA 2 input
Switch to VGA 2
50785%
Enable auto-switching
Auto Switching
50786%
Disable auto-switching
Manual Switching
Resolution Select Commands for VGA Input
Monitoring area, indicates
whether the command
sent works.